Division of Radiology, Mayo Clinic, Rochester, MN 55905, USA.
Citations 38
Short-term Automated Quantification of Radiologic Changes in the Characterization of Idiopathic Pulmonary Fibrosis Versus Nonspecific Interstitial Pneumonia and Prediction of Long-term Survival
Purpose: Fibrotic interstitial lung diseases presenting with nonspecific and overlapping radiologic findings may be difficult to diagnose without surgical biopsy. We hypothesized that baseline quantifiable radiologic features and their short-term interval change may be predictive of underlying histologic diagnosis as well as long-term survival in idiopathic pulmonary fibrosis (IPF) presenting without honeycombing versus nonspecific interstitial pneumonia (NSIP). Materials and Methods: Forty biopsy-confirmed IPF and 20 biopsy-confirmed NSIP patients with available high-resolution chest computed tomography 4 to 24 months apart were studied. CALIPER software was used for the automated characterization and quantification of radiologic findings. Results: IPF subjects were older (66 vs. 48; P<0.0001) with lower diffusion capacity for carbon monoxide and higher volumes of baseline reticulation (193 vs. 83 mL; P<0.0001). Over the interval period, compared with NSIP, IPF patients experienced greater functional decline (forced vital capacity, −6.3% vs. −1.7%; P=0.02) and radiologic progression, as noted by greater increase in reticulation volume (24 vs. 1.74 mL; P=0.048), and decrease in normal (−220 vs. −37.7 mL; P=0.045) and total lung volumes (−198 vs. 58.1 mL; P=0.03). Older age, male gender, higher reticulation volumes at baseline, and greater interval decrease in normal lung volumes were predictive of IPF. Both baseline and short-term changes in quantitative radiologic findings were predictive of mortality. Conclusions: Baseline quantitative radiologic findings and assessment of short-term disease progression may help characterize underlying IPF versus NSIP in those with difficult to differentiate clinicoradiologic presentations. Our study supports the possible utility of assessing serial quantifiable high-resolution chest computed tomographic findings for disease differentiation in these 2 entities.
Evaluation of visual and computer‐based CT analysis for the identification of functional patterns of obstruction and restriction in hypersensitivity pneumonitis
ABSTRACTBackground and objectiveTo determine whether computer‐based quantification (CALIPER software) is superior to visual computed tomography (CT) scoring in the identification of CT patterns indicative of restrictive and obstructive functional indices in hypersensitivity pneumonitis (HP).MethodsA total of 135 consecutive HP patients had CT parenchymal patterns evaluated quantitatively by both visual scoring and CALIPER. Results were evaluated against: forced vital capacity (FVC), total lung capacity (TLC), diffusing capacity for carbon monoxide (DLCO) and a composite physiological index (CPI) to identify which CT scoring method better correlated with functional indices.ResultsCALIPER‐derived scores of total interstitial lung disease extent correlated more strongly than visual scores: FVC (CALIPER R = 0.73, visual R = 0.51); DLCO (CALIPER R = 0.61, visual R = 0.48); and CPI (CALIPER R = 0·70, visual R = 0·55). The CT variable that correlated most strongly with restrictive functional indices was CALIPER pulmonary vessel volume (PVV): FVC R = 0.75, DLCO R = 0.68 and CPI R = 0.76.Ground‐glass opacity quantified by CALIPER alone demonstrated strong associations with restrictive functional indices: CALIPER FVC R = 0.65; DLCO R = 0.59; CPI R = 0.64; and visual = not significant. Decreased attenuation lung quantified by CALIPER was a better morphological measure of obstructive lung disease than equivalent visual scores as judged by relationships with TLC (CALIPER R = 0.63 and visual R = 0.12). All results were maintained on multivariate analysis.ConclusionCALIPER improved on visual scoring in HP as judged by restrictive and obstructive functional correlations. Decreased attenuation regions of the lung quantified by CALIPER demonstrated better linkages to obstructive lung physiology than visually quantified CT scores. A novel CALIPER variable, the PVV, demonstrated the strongest linkages with restrictive functional indices and could represent a new automated index of disease severity in HP.
Comparison of Total Lung Capacity Determined by Plethysmography With Computed Tomographic Segmentation Using CALIPER
Purpose: Traditionally, determination of total lung capacity (TLC) by plethysmography (TLCpleth) has been important in the diagnosis of lung diseases. Alternatively, data acquired from computerized tomography (CT) can be utilized to calculate a measure of TLC (TLCCT). The clinical utility of TLCCT is not certain. We sought to determine, in a clinical setting, whether TLCCT correlates with TLCpleth across a range of lung diseases and scanning techniques. In addition, we determined whether TLCCT affects the interpretation of pulmonary function tests. Subjects and Methods: Records of 118 of 148 consecutive lung transplant recipients were reviewed and determined to have coinciding pulmonary function tests, including plethysmography as well as volumetric chest CT performed supine during full inspiration. CT images acquired with a wide range of scanning protocols were analyzed using CALIPER, a software program for lung and trachea extraction from a CT volume and volumetric tissue characterization of the lung. Segmentation of the lung was achieved by using completely automated dynamic thresholding and region-growing techniques developed to extract the relatively low-density lung and tracheal anatomy from the CT data set without user intervention. Results: TLCpleth and TLCCT were strongly related with a correlation coefficient of 0.88 (P<0.001). The efficacy of the CT-derived measure was not influenced by specific lung diagnoses, age, height, body mass index, or spirometric parameters. TLCCT did not misidentify any diagnosis of restrictive lung disease, nor hyperinflation. Conclusions: In a clinical setting, CT segmentation analysis provides a favorable determination of TLC compared with traditional plethysmography. The technique has general applicability across varying CT data acquisition protocols, lung diseases, and patient characteristics. TLCCT may substitute for TLCpleth in pulmonary function interpretation and may be preferable for some patients in whom plethysmography is difficult to perform, such as transplant subjects with severe pulmonary fibrosis.
Automated Quantitative Computed Tomography Versus Visual Computed Tomography Scoring in Idiopathic Pulmonary Fibrosis
Purpose: The aim of the study was to determine whether a novel computed tomography (CT) postprocessing software technique (CALIPER) is superior to visual CT scoring as judged by functional correlations in idiopathic pulmonary fibrosis (IPF). Materials and Methods: A total of 283 consecutive patients with IPF had CT parenchymal patterns evaluated quantitatively with CALIPER and by visual scoring. These 2 techniques were evaluated against: forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), diffusing capacity for carbon monoxide (DLco), carbon monoxide transfer coefficient (Kco), and a composite physiological index (CPI), with regard to extent of interstitial lung disease (ILD), extent of emphysema, and pulmonary vascular abnormalities. Results: CALIPER-derived estimates of ILD extent demonstrated stronger univariate correlations than visual scores for most pulmonary function tests (PFTs): (FEV1: CALIPER R 2=0.29, visual R 2=0.18; FVC: CALIPER R 2=0.41, visual R 2=0.27; DLco: CALIPER R 2=0.31, visual R 2=0.35; CPI: CALIPER R 2=0.48, visual R 2=0.44). Correlations between CT measures of emphysema extent and PFTs were weak and did not differ significantly between CALIPER and visual scoring. Intriguingly, the pulmonary vessel volume provided similar correlations to total ILD extent scored by CALIPER for FVC, DLco, and CPI (FVC: R 2=0.45; DLco: R 2=0.34; CPI: R 2=0.53). Conclusions: CALIPER was superior to visual scoring as validated by functional correlations with PFTs. The pulmonary vessel volume, a novel CALIPER CT parameter with no visual scoring equivalent, has the potential to be a CT feature in the assessment of patients with IPF and requires further exploration.
Syntactic and semantic errors in radiology reports associated with speech recognition software
Speech recognition software can increase the frequency of errors in radiology reports, which may affect patient care. We retrieved 213,977 speech recognition software–generated reports from 147 different radiologists and proofread them for errors. Errors were classified as “material” if they were believed to alter interpretation of the report. “Immaterial” errors were subclassified as intrusion/omission or spelling errors. The proportion of errors and error type were compared among individual radiologists, imaging subspecialty, and time periods. In all, 20,759 reports (9.7%) contained errors, of which 3992 (1.9%) were material errors. Among immaterial errors, spelling errors were more common than intrusion/omission errors ( p < .001). Proportion of errors and fraction of material errors varied significantly among radiologists and between imaging subspecialties ( p < .001). Errors were more common in cross-sectional reports, reports reinterpreting results of outside examinations, and procedural studies (all p < .001). Error rate decreased over time ( p < .001), which suggests that a quality control program with regular feedback may reduce errors.
Noninvasive Computed Tomography–based Risk Stratification of Lung Adenocarcinomas in the National Lung Screening Trial
Abstract Rationale Screening for lung cancer using low-dose computed tomography (CT) reduces lung cancer mortality. However, in addition to a high rate of benign nodules, lung cancer screening detects a large number of indolent cancers that generally belong to the adenocarcinoma spectrum. Individualized management of screen-detected adenocarcinomas would be facilitated by noninvasive risk stratification. Objectives To validate that Computer-Aided Nodule Assessment and Risk Yield (CANARY), a novel image analysis software, successfully risk stratifies screen-detected lung adenocarcinomas based on clinical disease outcomes. Methods We identified retrospective 294 eligible patients diagnosed with lung adenocarcinoma spectrum lesions in the low-dose CT arm of the National Lung Screening Trial. The last low-dose CT scan before the diagnosis of lung adenocarcinoma was analyzed using CANARY blinded to clinical data. Based on their parametric CANARY signatures, all the lung adenocarcinoma nodules were risk stratified into three groups. CANARY risk groups were compared using survival analysis for progression-free survival. Measurements and Main Results A total of 294 patients were included in the analysis. Kaplan-Meier analysis of all the 294 adenocarcinoma nodules stratified into the Good, Intermediate, and Poor CANARY risk groups yielded distinct progression-free survival curves (P < 0.0001). This observation was confirmed in the unadjusted and adjusted (age, sex, race, and smoking status) progression-free survival analysis of all stage I cases. Conclusions CANARY allows the noninvasive risk stratification of lung adenocarcinomas into three groups with distinct post-treatment progression-free survival. Our results suggest that CANARY could ultimately facilitate individualized management of incidentally or screen-detected lung adenocarcinomas.
Iodixanol Versus Low-Osmolar Contrast Media for Prevention of Contrast Induced Nephropathy
Background— Contrast-induced nephropathy (CIN) is associated with significant morbidity and mortality. The objective of our meta-analysis was to assess the efficacy of iodixanol compared with low-osmolar contrast media (LOCM) for prevention of CIN. Methods and Results— We searched MEDLINE, the Cochrane Central Register of Controlled Trials, and internet sources of cardiology trial results for individual and relevant reviews of randomized, controlled trials, for the terms contrast media, contrast nephropathy, renal failure, iodixanol, Visipaque, and low-osmolar contrast media. All studies reported an incidence rate of CIN for each study group; there was no restriction on the definition of CIN. There were no restrictions on journal type or patient population. Overall, 36 trials were identified for analysis of aggregated summary data on 7166 patients; 3672 patients received iodixanol and 3494 patients received LOCM. Overall, iodixanol showed no statistically significant reduction in CIN incidence below that observed with heterogeneous comparator agents ( P =0.11). Analysis of patient subgroups revealed that there was a significant benefit of iodixanol when compared with iohexol alone (odds ratio, 0.25; 95% confidence interval, 0.11 to 0.55; P <0.001) but not when compared with LOCM other than iohexol or with other ionic dimers or among patients receiving intra-arterial contrast injections or among patients undergoing coronary angiography with or without percutaneous intervention. Conclusions— Analysis of aggregated summary data from multiple randomized, controlled trials of iodixanol against diverse LOCMs for heterogeneous procedures and definitions of CIN show an iodixanol-associated reduction that is suggestive but statistically nonsignificant.
Iodixanol compared to iohexol for contrast procedures: a case-matched retrospective cohort study
Background: Previous studies that have attempted to evaluate the effectiveness of an iso-osmolar contrast medium (IOCM) iodixanol compared to a low-osmolar contrast medium (LOCM) for contrast procedures show variable results. Purpose: To evaluate the nephrotoxicity of the IOCM iodixanol compared to the LOCM iohexol. Material and Methods: We performed a retrospective cohort study from April 2004 to March 2006. All contrast procedures with a pre- and post-exposure creatinine value were evaluated for inclusion. Contrast nephropathy (CN) was defined as post-exposure creatinine elevation of ≥25% or >0.5 mg/dl within 7 days of contrast exposure. Cases of iodixanol exposure were matched to control cases of iohexol exposure (1:1) based on age, sex, presence of diabetes, pre-exposure creatinine value, and type of imaging study performed. We matched 397 cases of iodixanol (IOCM) exposure to 397 cases of iohexol (LOCM) exposure. Cases of iodixanol which could not be matched to controls were not included in the analysis. Results: After adjustment for prior creatinine, medications, contrast iodine load, prior exposure to contrast material, heart failure, and hypertension, use of iodixanol did not significantly alter rates of CN compared to iohexol (OR 0.92, 95% CI 0.57–1.46; P=0.71) or mortality (RR 0.79, 95% CI 0.59–1.06; P=0.12). Conclusion: The use of the IOCM iodixanol was not associated with statistically significant protection against contrast nephropathy or all-cause mortality compared to a matched cohort of patients receiving the LOCM iohexol.