Back to Authors

Pichelmann, Mark A.

Mayo Clinic

Mayo Clinic

Citations 14

Endovascular Coil Occlusion of Ruptured Saccular Cerebral Aneurysms Using Guglielmi Detachable Coils
Friedman, Jonathan A., Nichols, D A, Meyer, Fredric B. , Pichelmann, Mark A., McIver, Jon I., Toussaint, L. Gerard , Axley, P L, Brown, Robert D.

Rivista di Neuroradiologia | April 22, 2015 | Volume: 16 | Issue: 6 | Pages: 1213-1222

10.1177/197140090301600649 Get It

Intraoperative image-guided spinal navigation: technical pitfalls and their avoidance
Rahmathulla, Gazanfar , Nottmeier, Eric W. , Pirris, Stephen M. , Deen, H. Gordon , Pichelmann, Mark A.

Neurosurgical Focus | March 1, 2014 | Volume: 36 | Issue: 3 | Pages: E3

10.3171/2014.1.focus13516 Get It

Spinal instrumentation has made significant advances in the last two decades, with transpedicular constructs now widely used in spinal fixation. Pedicle screw constructs are routinely used in thoracolumbar-instrumented fusions, and in recent years, the cervical spine as well. Three-column fixations with pedicle screws provide the most rigid form of posterior stabilization. Surgical landmarks and fluoroscopy have been used routinely for pedicle screw insertion, but a number of studies reveal inaccuracies in placement using these conventional techniques (ranging from 10% to 50%). The ability to combine 3D imaging with intraoperative navigation systems has improved the accuracy and safety of pedicle screw placement, especially in more complex spinal deformities. However, in the authors' experience with image guidance in more than 1500 cases, several potential pitfalls have been identified while using intraoperative spinal navigation that could lead to suboptimal results. This article summarizes the authors' experience with these various pitfalls using spinal navigation, and gives practical tips on their avoidance and management.
Small cerebral aneurysms presenting with symptoms other than rupture
Friedman, Jonathan A., Piepgras, D. G., Pichelmann, Mark A., Hansen, Kristine K., Brown, Robert D., Wiebers, David O.

Neurology | May 13, 2012 | Volume: 57 | Issue: 7 | Pages: 1212-1216

10.1212/wnl.57.7.1212 Get It

Durability of Carotid Endarterectomy
Ecker, Robert D., Pichelmann, Mark A., Meissner, Irene, Meyer, Fredric B.

Stroke | November 18, 2003 | Volume: 34 | Issue: 12 | Pages: 2941-2944

10.1161/01.str.0000098903.93992.49 Get It

Background and Purpose—We sought to determine the incidence of recurrent stenosis after carotid endarterectomy.Methods—One thousand consecutive carotid endarterectomy patients were followed prospectively. The surgery was performed in a standard fashion. Cerebral protection was provided with intraoperative electroencephalographic monitoring and selective shunting. All arteriotomies were repaired with a patch graft. Each patient was seen 3 months after surgery and then yearly, with a duplex ultrasound obtained at each visit. Evidence for new ischemic events or recurrent stenosis of ≥70% was recorded.Results—The 30-day combined minor and major stroke and death rate was 1.9%. At 7.1-year follow-up, 0.1% of patients had recurrent stenosis ≥70%, the majority of which were asymptomatic.Conclusions—Carotid endarterectomy is a low-risk procedure for the treatment of carotid occlusive disease, with excellent long-term durability. Although less invasive, carotid angioplasty must demonstrate equal robustness in long-term follow-up before it is considered a routine alternative to surgery.