Back to Authors

Maldonado, Andres A.

0000-0002-3703-5667

Mayo Clinic

Mayo Clinic

Citations 14

Proposed surgical technique to facilitate targeted reinnervation of the infraspinatus: A cadaveric feasibility study
Wyles, Cody C. , Maldonado, Andrés A. , Wagner, Eric R. , Lachman, Nirusha , Spinner, Robert J. , Lachman, Nirusha , Spinner, Robert J , Wagner, Eric R , Wyles, Cody C , Houdek, Matthew T. , Maldonado, Andres A.

Clinical Anatomy | October 26, 2018 | Volume: 32 | Issue: 1 | Pages: 131-136

10.1002/ca.23310 Get It

Restoration of shoulder lateral rotation remains a significant challenge following brachial plexus injury. Transfer of the accessory nerve to suprascapular nerve (SSN) has been widely performed, although with generally poor outcomes for lateral rotation. A recent report suggested a selective infraspinatus reinnervation technique using a radial nerve branch for SSN transfer. This cadaveric study was performed in 7 specimens (14 shoulders). We present technical modifications to achieve additional length to the recipient nerve (suprascapular) that would facilitate direct repair. Key elements of the technique are (1) isolation of the SSN immediately distal to its motor branch to supraspinatus near the superior transverse scapular ligament; and (2) delivery of the transected SSN through the spinoglenoid notch and deep to the infraspinatus for emergence in the infraspinatus‐teres minor interval. Nerve overlap of at least 21 mm was observed in all 14 dissected shoulders between the harvested SSN and radial nerve branches. The mean nerve overlap between harvested branches was 26 mm (range 21–32 mm). The mean harvested SSN length was 59 mm (range 46–80 mm). The mean length of the harvested radial nerve branch was 72 mm (range 65–85 mm). No measurements were significantly different between left and right shoulders or between males and females (smallest P value = 0.1249). Nerve diameter of the two harvested branches was judged to be appropriately compatible for surgical coaptation in all 14 dissected shoulders. We present a variation on a described technique to increase recipient suprascapular nerve length. Additional length of the recipient nerve is achieved through utilization of a more proximal dissection of the suprascapular nerve near the level of the superior transverse scapular ligament and delivering the nerve through the teres minor‐infraspinatus interval. These surgical modifications are of clinical interest when selective reinnervation of the infraspinatus muscle is considered. We believe such a targeted approach can potentially increase shoulder lateral rotation function. Clin. Anat. 32:131–136, 2019. © 2018 Wiley Periodicals, Inc.
“Isolated” Suprascapular Neuropathy: Compression, Traction, or Inflammation?
Maldonado, Andrés A. , Howe, Benjamin M. , Mauermann, Michelle L. , Spinner, Robert J. , Le Hanneur, Malo, Mauermann, Michelle L , Hanneur, Malo Le , Maldonado, Andres A.

Neurosurgery | January 30, 2018 | Volume: 84 | Issue: 2 | Pages: 404-412

10.1093/neuros/nyy050 Get It

Abstract BACKGROUND Several hypotheses have been proposed for the pathophysiology of suprascapular nerve (SSN) palsy, including compression, traction, and nerve inflammation. OBJECTIVE To provide insight into the pathophysiology of isolated nontraumatic SSN palsy by performing critical reinterpretations of electrodiagnostic (EDX) studies and magnetic resonance (MR) images of patients with such diagnosis. METHODS We retrospectively reviewed all patients referred to our institution for the past 20 yr with a diagnosis of nontraumatic isolated suprascapular neuropathy who had an upper extremity EDX study and a shoulder or brachial plexus MR scan. Patient charts were reviewed to analyze their initial clinical examination, and their original EDX study and MR images were reinterpreted by an experienced neurologist and a musculoskeletal radiologist, respectively, both blinded from the authors’ hypothesis and from each other's findings. RESULTS Fifty-nine patients were included. Fifty of them (85%) presented with at least 1 finding that was inconsistent with an isolated SSN palsy. Forty patients (68%) had signs on physical examination beyond the SSN distribution. Thirty-one patients (53%) had abnormalities on their EDX studies not related to the SSN. Twenty-two patients (37%) had denervation atrophy in other muscles than the spinati, or neural hyperintensity in other nerves than the SSN on their MR scans, without any evidence of SSN extrinsic compression. CONCLUSION The great majority of patients with presumed isolated SSN palsy had clinical, electrophysiological, and/or imaging evidence of a more diffuse pattern of neuromuscular involvement. These data strongly support an inflammatory pathophysiology in many cases of “isolated” SSN palsy.
Delayed compression of the common peroneal nerve following rotational lateral gastrocnemius flap: case report
Wilson, Thomas J. , Maldonado, Andrés A. , Murthy, Naveen S. , Spinner, Robert J. , Himes, Benjamin , Maldonado, Andres A.

Journal of Neurosurgery | July 28, 2017 | Volume: 128 | Issue: 5 | Pages: 1589-1592

10.3171/2017.2.jns162711 Get It

The authors present a case of delayed peroneal neuropathy following a lateral gastrocnemius rotational flap reconstruction. The patient presented 1.5 years after surgery with a new partial foot drop, which progressed over 3 years. At operation, a fascial band on the deep side of the gastrocnemius flap was compressing the common peroneal nerve proximal to the fibular head, correlating with preoperative imaging. Release of this fascial band and selective muscle resection led to immediate improvement in symptoms postoperatively.
A novel method of lengthening the accessory nerve for direct coaptation during nerve repair and nerve transfer procedures
Tubbs, R. Shane , Maldonado, Andrés A. , Stoves, Yolanda, Fries, Fabian N. , Li, Rong , Loukas, Marios , Oskouian, Rod J. , Spinner, Robert J. , Maldonado, Andres A.

Journal of Neurosurgery | March 3, 2017 | Volume: 128 | Issue: 1 | Pages: 272-276

10.3171/2016.10.jns161106 Get It

OBJECTIVEThe accessory nerve is frequently repaired or used for nerve transfer. The length of accessory nerve available is often insufficient or marginal (under tension) for allowing direct coaptation during nerve repair or nerve transfer (neurotization), necessitating an interpositional graft. An attractive maneuver would facilitate lengthening of the accessory nerve for direct coaptation. The aim of the present study was to identify an anatomical method for such lengthening.METHODSIn 20 adult cadavers, the C-2 or C-3 connections to the accessory nerve were identified medial to the sternocleidomastoid (SCM) muscle and the anatomy of the accessory nerve/cervical nerve fibers within the SCM was documented. The cervical nerve connections were cut. Lengths of the accessory nerve were measured. Samples of the cut C-2 and C-3 nerves were examined using immunohistochemistry.RESULTSThe anatomy and adjacent neural connections within the SCM are complicated. However, after the accessory nerve was “detethered” from within the SCM and following transection, the additional length of the accessory nerve increased from a mean of 6 cm to a mean of 10.5 cm (increase of 4.5 cm) after cutting the C-2 connections, and from a mean of 6 cm to a mean length of 9 cm (increase of 3.5 cm) after cutting the C-3 connections. The additional length of accessory nerve even allowed direct repair of an infraclavicular target (i.e., the proximal musculocutaneous nerve). The cervical nerve connections were shown not to contain motor fibers.CONCLUSIONSAn additional length of the accessory nerve made available in the posterior cervical triangle can facilitate direct repair or neurotization procedures, thus eliminating the need for an interpositional nerve graft, decreasing the time/distance for regeneration and potentially improving clinical outcomes.