Evaluation of Fracture Resistance in Aqueous Environment under Dynamic Loading of Lithium Disilicate Restorative Systems for Posterior Applications. Part 2
AbstractPurposeThe goals of part 2 of the study presented here were 1) to assess whether there is a difference in failure mode of different thicknesses (2.0, 1.5, 1.0, and 0.5 mm) of anatomically standardized full contour monolithic lithium disilicate restorations for posterior teeth, and 2) to assess if there is a difference among various crown thicknesses when these restorations are subjected to dynamic load forces common for posterior teeth.Materials and MethodsFour groups (n = 10), each with a different thickness of anatomically appropriate all‐ceramic crowns, were to be tested as established from the statistical analysis of the preliminary phase. Group 1: 2.0 mm; group 2: 1.5 mm; group 3: 1.0 mm; group 4: 0.5 mm. The specimens were adhesively luted to the corresponding die, and underwent dynamic cyclic loading (380 to 390 N) completely submerged in an aqueous environment until a failure was noted by graphic recording and continuous monitoring.ResultsThere was a statistically significant difference of the fatigue cycles to failure among four groups (p < 0.001; Kruskal‐Wallis test). The mean number of cycles to fail for 2.0 mm specimens was 17 times more than the mean number of cycles to fail for 1.0 mm specimens and 1.5 times more than the mean number of cycles to fail for 1.5 mm specimens. The 0.5 mm specimens failed with one cycle of loading. A qualitative characteristic noted among the 2.0 mm specimens was wear of the area of indenter contact followed by shearing of the material and/or crack propagation.ConclusionBased on the findings of this study, it may be reasonable to consider a crown thickness of 1.5 mm or greater for clinical applications of milled monolithic lithium disilicate crowns for posterior single teeth.
Practice‐Based Evidence from 29‐Year Outcome Analysis of Management of the Edentulous Jaw Using Osseointegrated Dental Implants
AbstractPurposeThe aim of this retrospective study was to summarize practice‐based evidence associated with long‐term outcomes (>20 years) in the management of edentulous patients. The patient population was managed with implant‐supported prostheses, following the original osseointegration protocol, provided over the period from 1983 to 1991 in the group prosthodontics practice at the Mayo Clinic. The data are an example of practice quality assurance monitoring and are used to refine care delivery when needed and to provide information regarding expected outcomes in a shared decision‐making interaction with prospective patients.Materials and MethodsTwo hundred and sixty four patients with at least one edentulous jaw were identified. Of these, 255 completed their care and follow‐up at the Mayo Clinic (209 mandible only, 35 maxilla only, 11 mandible and maxilla). Prosthodontic outcomes categorized as anticipated or unanticipated prosthetic and biologic events and the respective interventions required for each were recorded to assess follow‐up event dynamics for this care modality.ResultsThe mean duration of follow‐up for 190 of the 255 patients (65 died at a mean follow‐up of 12.6 years) was 13.0 years (median 13.6; range 0.3 to 28). At least one prosthetic event was experienced by 148 patients (58%), and 81 (32%) experienced at least one biologic event. Overall, patients experienced 3.8 times more prosthetic events than biologic events. Twenty‐four (9%) patients experienced 35 implant failures. Overall survival rates at 20 years were 86% for prostheses, 15% survived free of any event, and 92% experienced survival free of implant failure (95% confidence interval).ConclusionAnticipated and unanticipated prosthetic events occur throughout the life of the hybrid prosthesis. Prosthetic events significantly surpass (four times more) biologic events and occur significantly later in the follow‐up. For this patient group, 8.6% (22/255) had implant‐supported prostheses remade during follow‐up in this patient population. These findings support the recommendation that prosthodontic care for missing teeth be thought of in a “chronic condition” context, recognizing that long‐term outcome monitoring to provide realistic care expectations is important for demonstrating care value in oral health promotion.
Human Calmodulin-Like Protein CALML3: A Novel Marker for Normal Oral Squamous Mucosa That Is Downregulated in Malignant Transformation
Oral cancer is often diagnosed only at advanced stages due to a lack of reliable disease markers. The purpose of this study was to determine if the epithelial-specific human calmodulin-like protein (CALML3) could be used as marker for the various phases of oral tumor progression. Immunohistochemical analysis using an affinity-purified CALML3 antibody was performed on biopsy-confirmed oral tissue samples representing these phases. A total of 90 tissue specimens were derived from 52 patients. Each specimen was analyzed in the superficial and basal mucosal cell layers for overall staining and staining of cellular subcompartments. CALML3 was strongly expressed in benign oral mucosal cells with downregulation of expression as squamous cells progress to invasive carcinoma. Based on the Cochran-Armitage test for trend, expression in the nucleus and at the cytoplasmic membrane significantly decreased with increasing disease severity. Chi-square test showed that benign tissue specimens had significantly more expression compared to dysplasia/CIS and invasive specimens. Dysplasia/CIS tissue had significantly more expression than invasive tissue. We conclude that CALML3 is expressed in benign oral mucosal cells with a statistically significant trend in downregulation as tumorigenesis occurs. CALML3 may thus be a sensitive new marker for oral cancer screening.
Evaluation of Fracture Resistance in Aqueous Environment of Four Restorative Systems for Posterior Applications. Part 1
AbstractPurposeThe goals of this study were to: (1) establish a range of the performance of four restorative systems for posterior single‐tooth crowns under single load to fracture submerged in an aqueous environment, (2) identify restorative system(s) of interest to be examined in the second study phase under sliding contact step‐stress fatigue as full‐contour anatomically appropriate single posterior tooth restoration(s), (3) establish a range for loading/testing for phase 2.Materials and MethodsForty specimens (n = 10/group) of 2 mm uniform thickness were tested. Group 1: monolithic lithium disilicate IPS e.max Press; group 2: IPS e.max ZirPress, 0.8 mm zirconia core with 1.2 mm pressed veneering porcelain; group 3: IPS e.max ZirPress, 0.4 mm zirconia core with 1.6 mm pressed veneering porcelain; group 4: IPS InLine PoM. Specimens were bonded to a block of polycast acrylic resin on a 30° sloped surface with resin cement. Specimens were axially single loaded to failure while submerged under water.ResultsThere was a statistically significant difference (p < 0.001) in failure load among the four restorative systems. Lithium disilicate showed a mean failure load similar to mean maximum posterior bite forces (743.1 ± 114.3 N). IPS e.max Zirpress with a 0.4 mm zirconia core exhibited the lowest mean failure load (371.4 ± 123.0 N).ConclusionFracture resistance of monolithic lithium disilicate in an aqueous environment is promising and requires second phase testing to evaluate the potential of various thicknesses appropriate for posterior single tooth applications. Doubling the IPS e.max Zirpress zirconia core from 0.4 mm to 0.8 mm increased the fracture resistance of this restorative system threefold.
Interventions for tobacco cessation in the dental setting