Back to Authors

McMahon, M. Molly

https://orcid.org/0009-0002-3700-7524

Mayo Clinic

Mayo Clinic

Citations 15

42nd ASPEN President's Address: Nutrition Support: Integrating Technology and Clinical Expertise
McMahon, M. Molly

Journal of Parenteral and Enteral Nutrition | May 29, 2018 | Volume: 42 | Issue: 8 | Pages: 1230-1236

10.1002/jpen.1301 Get It

Underestimation of Glucose Turnover Measured With [6-3H]- and [6,6-2 H2]- but not [6-14C]glucose During Hyperinsulinemia in Humans
McMahon, M. Molly , Schwenk, W Frederick, Haymond, Morey W. , Rizza, Robert A., Schwenk, W Frederick

Diabetes | September 19, 2013 | Volume: 38 | Issue: 1 | Pages: 97-107

10.2337/diab.38.1.97 Get It

Recent studies indicate that hydrogen-labeled glucose tracers underestimate glucose turnover in humans under conditions of high flux. The cause of this underestimation is unknown. To determine whether the error is time-, pool-, model-, or insulin-dependent, glucose turnover was measured simultaneously with [6-3H]-, [6,6-2H2]-, and [6-14C]glucose during a 7-h infusion of either insulin (1 mU · kg−1 · min−1) or saline. During the insulin infusion, steady-state glucose turnover measured with both [6-3H]glucose (8.0 ± 0.5 mg · kg−1 · min−1) and [6,6-2H2]glucose (7.6 ± 0.5 mg kg−1 min−1) was lower (P < .01) than either the glucose infusion rate required to maintain euglycemia (9.8 ± 0.6 mg · kg−1 · min−1) or glucose turnover determined with [6-14 C]glucose and corrected for Cori cycle activity (9.8 ± 0.7 mg · kg−1 · min1). Consequently “negative” glucose production rates (P <.01) were obtained with either [6-3 H]- or [6,6-2 H2]-but not [6-14 C]glucose. The difference between turnover estimated with [6-3 H]glucose and actual glucose disposal (or 14C glucose flux) did not decrease with time and was not dependent on duration of isotope infusion. During saline infusion, estimates of glucose turnover were similar regardless of the glucose tracer used. High-performance liquid chromatography of the radioactive glucose tracer and plasma revealed the presence of a tritiated nonglucose contaminant. Although the contaminant represented only 1.5% of the radioactivity in the [6-3H]glucose infusate, its clearance was 10-fold less (P <.001) than that of [6-3H]glucose. This resulted in accumulation in plasma, with the contaminant accounting for 16.6 ± 2.09 and 10.8 ± 0.9% of what customarily is assumed to be plasma glucose radioactivity during the insulin or saline infusion, respectively (P < .01). When corrected for the presence of the contaminant, glucose turnover determined with [6-3H]glucose during insulin infusion (9.5 ± 0.6 mg · kg−1 · min−1) no longer differed from either the glucose infusion rate or that determined with [6-14C]glucose. Therefore, the underestimation of glucose turnover during insulin infusion and negative glucose production rates observed with traditional methods to analyze plasma radioactivity and commercially available tracers is the result of an artifactual increase in [6-3H]glucose specific activity. The etiology of the underestimation of glucose turnover with [6,6-2H2]glucose remains to be determined.
Intensive Intraoperative Insulin Therapy versus Conventional Glucose Management during Cardiac Surgery
Gandhi, Gunjan Y. , Nuttall, Gregory A. , Mullany, Charles J., Schaff, Hartzell V. , O’Brien, Peter C. , Johnson, Matthew G. , Cutshall, Susanne M. , Rizza, Robert A., McMahon, M. Molly , Williams, Arthur Robin , Mundy, Lisa K. , Schaff, Hartzell

Annals of Internal Medicine | April 12, 2013 | Volume: 146 | Issue: 4 | Pages: 233-243

10.7326/0003-4819-146-4-200702200-00002 Get It

Intensive insulin therapy reduced mortality and morbidity in critically ill patients
Hurley, Daniel L. , McMahon, M. Molly

ACP Journal Club | April 11, 2013 | Volume: 136 | Issue: 3 | Pages: 81

10.7326/acpjc-2002-136-3-081 Get It

Hyperglycemia in Acute Illness—Reply
McMahon, M. Molly , Montori, Víctor M. , Bistrian, Bruce R.

JAMA | March 18, 2003 | Volume: 289 | Issue: 10 | Pages: 1244

10.1001/jama.289.10.1244-b Get It