Abstract TP82: Changes in the Distal Vessel Wall After Flow Diverter Treatment
Parameswaran, Praveen Kolumam, Ding, Yong Hong, Asnafi, Solmaz , Urban, Matthew M, Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Ding, Yonghong

Stroke | October 8, 2018 | Volume: 49 | Issue: Suppl_1 | Pages: No page available

10.1161/str.49.suppl_1.tp82 Get It

Background: Flow diverters (FD) are increasingly used in the treatment of intracranial aneurysms. The risk of distal thromboembolic complications with FD is high, even in patients treated with dual antiplatelet therapy. The aim of the study was to understand the downstream vascular wall changes, by measuring the pulse wave velocity and vascular contractility following flow diverter treatment in a rabbit model. Methods: FD (Pipeline Embolic Device, Medtronic) were implanted in normal rabbits and sham-operated aorta were used as controls (n=5 for each group). Pulse wave imaging with ultra-fast ultrasound at 1600 frames per second (Vantage, Verasonics, Inc.) was performed in the vessel wall distal to FD, prior to device implantation and at 8 weeks follow up to measure the pulse wave propagation. Force contraction studies were conducted in the aortic rings using organ bath to assess the vascular functions. Results: The difference in pulse wave velocity (PWV) in the follow-up compared to pre-implantation was significantly higher (p=0.03,Fig 1A) in the distal vessels compared to sham controls (mean difference of PWV was 1.18 m/s and -0.37m/s, respectively as shown in Fig 1B). Conversely, the distal aortic segments to FD exhibited 55% increase in the level of vascular contractility compared to that of proximal segments (p=0.002). There is a significant positive correlation between mean PWV and mean vascular contractility. Conclusion: Our study found changes in the PWV after implantation of the FD, which correlated with vascular contractility. These results could explain vascular wall changes downstream following FD implantation.
Assessment of endothelialization of aneurysm wall over time in a rabbit model through CD31 scoring
Parameswaran, Praveen Kolumam, Ding, Yong-Hong, Gunderson, Tina M. , Kallmes, David F. , Kadirvel, Ramanathan , Kolumam Parameswaran, Praveen, Dai, Daying , Gunderson, Tina, Ding, Yonghong

Journal of NeuroInterventional Surgery | December 29, 2017 | Volume: 10 | Issue: 9 | Pages: 888-891

10.1136/neurintsurg-2017-013381 Get It

Background Intracranial aneurysms represent a significant health concern and are poorly understood despite decades of research. Our study focused on understanding temporal patterns of endothelial cell distribution in different spatial locations within the aneurysm early after creation in a rabbit model. Methods Elastase induced saccular aneurysms were created in rabbits and harvested on day 1 (n=3) and after 2 (n=5), 4 (n=4), 8 (n=5), and 12 (n=6) weeks. Sham operated controls (n=3) were harvested on the same day. Aneurysm and control tissue samples were subjected to en face whole mount CD31 staining for endothelial cells. Semiquantitative scoring was performed on the basis of endothelial coverage of the vessel wall (proximal, middle, and distal portions of the aneurysm dome). Mixed effects models were used to assess the effect of time and aneurysm section on endothelial coverage. Results Aneurysmal segments were near completely de-endothelialized at 4 and 8 weeks but had re-endothelialized by 12 weeks. Compared with controls, aneurysms at all time points showed decreased endothelialization, but the difference was only significant compared with the 4 and 8 week groups. Both time (P=0.03) and aneurysm section (P=0.07) were significantly associated with the degree of endothelialization. Proximal locations showed increased endothelialization compared with distal locations (P=0.03). Conclusion In experimental aneurysms of rabbits, endothelial cells regress during the first month after creation, followed by ascending re-endothelialization that stays incomplete. These findings suggest that re-population of endothelial cells comes from resident cells in the adjacent parent artery and that deranged hemodynamics may affect full reconstitution of endothelial cells long term.
Increased X-ray Visualization of Shape Memory Polymer Foams by Chemical Incorporation of Iodine Motifs
Nash, Landon D., Monroe, Mary, Ding, Yong-Hong, Ezell, Kendal P., Boyle, Anthony, Kadirvel, Ramanathan , Kallmes, David F. , Maitland, Duncan J. , Ding, Yonghong

Polymers | August 21, 2017 | Volume: 9 | Issue: 8 | Pages: 381

10.3390/polym9080381 Get It

Shape memory polymers can be programmed into a secondary geometry and recovered to their primary geometry with the application of a controlled stimulus. Porous shape memory polymer foam scaffolds that respond to body temperature show particular promise for embolic medical applications. A limitation for the minimally invasive delivery of these materials is an inherent lack of X-ray contrast. In this work, a triiodobenzene containing a monomer was incorporated into a shape memory polymer foam material system to chemically impart X-ray visibility and increase material toughness. Composition and process changes enabled further control over material density and thermomechanical properties. The proposed material system demonstrates a wide range of tailorable functional properties for the design of embolic medical devices, including X-ray visibility, expansion rate, and porosity. Enhanced visualization of these materials can improve the acute performance of medical devices used to treat vascular malformations, and the material porosity provides a healing scaffold for durable occlusion.
Concomitant aneurysm detection in an intracranial dolichoectasia mouse model using a MicroFil polymer perfusion technique
Zhu, Yue-Qi, Dai, Da-Ying, Xing, H , Ding, Yong-Hong, Kadirvel, Ramanathan , Kallmes, David F. , Xing, Hai-Xia, Zhu, Yue-Qi, Dai, Daying , Ding, Yonghong

Journal of NeuroInterventional Surgery | July 5, 2016 | Volume: 9 | Issue: 8 | Pages: 783-786

10.1136/neurintsurg-2016-012469 Get It

Objective To assess the feasibility of using MicroFil polymer perfusion to detect concomitant saccular aneurysms in an intracranial arterial dolichoectasia (IADE) model in mice, and to report detailed histomorphometric features of these aneurysms. Materials and methods IADE models were created in C57/BL6 mice via microsurgical injection of 25 mU elastase into the cisterna magna. The cerebral vasculature was perfused with MicroFil polymer and harvested at 1, 3, and 7 days, and 2 and 4 weeks (n=8 for each group). IADE was defined by a tortuosity index >10 combined with a 25% increase in diameter of the A1 segment of the anterior cerebral artery (ACA), internal carotid artery (ICA), or basilar artery compared with the baseline of controls, which received heat-inactivated elastase. Saccular aneurysm occurrence rate, location, and morphological parameters were investigated using macroscopic and microscopic analysis. Results IADE was present in 95% (36/38) of the subjects, with a mortality rate of 5% (2/40). Fifteen concomitant saccular aneurysms were detected in 8 (21%) of the 38 surviving mice, including 6 at the posterior communicating artery, 1 along the ACA, 2 along the anterior communicating artery complex, 3 along the ICA, and 3 along the middle cerebral artery. Rupture was confirmed in two aneurysms. Histological examination indicated that the aneurysms develop via arterial-wall remodelling, which is characterized by internal elastic lamina disruptions and muscular layer discontinuity in the media. Conclusions The proportion of subjects developing saccular aneurysms in addition to IADE in our mouse model is similar to the 15% of patients with IADE who have concomitant saccular aneurysms.
O-023 experimental testing of new generation of woven endobridge devices in elastase-induced aneurysms in rabbits
Schroeder, Dana , Kadirvel, Ramanathan , Kallmes, D, Ding, Yonghong , Dai, Daying

Oral abstracts | June 8, 2016 | Volume: No volume available | Issue: No issue available | Pages: A12-A12

10.1136/neurintsurg-2015-011917.23 Get It

Experimental testing of the dual-layer Woven EndoBridge device using an elastase-induced aneurysm model in rabbits
Ding, Yong-Hong, Schroeder, Dana , Kadirvel, Ramanathan , Kallmes, David F. , Dai, Daying , Ding, Yonghong

Interventional Neuroradiology | February 4, 2016 | Volume: 22 | Issue: 3 | Pages: 299-303

10.1177/1591019916628202 Get It

The dual-layer Woven EndoBridge (WEB) device (WEB II) is designed to improve the performance of the first-generation WEB device. This study was performed to evaluate the acute and chronic performance of WEB II for aneurysm occlusion in an elastase-induced aneurysm model in rabbits. We implanted WEB II devices in 36 elastase-induced aneurysms and followed up for one, three, six, and 12 months. Degree of aneurysm occlusion at follow-up was graded on the Web Occlusion Scale (WOS): Grade A, complete aneurysm occlusion; Grade B, complete occlusion with recess filling; Grade C, residual neck filling; and Grade D, residual aneurysm filling. Hematoxylin and eosin staining was performed for histological assessment of aneurysm healing. Grades A, B, C, and D aneurysm occlusion at one-month follow-up were noted in three (17%), three (17%), eight (44%), and four (22%) of 18 cases, respectively. At the three-month time point Grades A, B, C, and D were shown in two (33%), two (33%), one (17%), and one (17%) aneurysms. Six months after treatment, one (17%), two (33%), two (33%), and one (17%) cases demonstrated Grades A, B, C, and D occlusion. At the 12-month time point, Grades B, C, and D were shown in three (50%), two (33%), and one (17%) aneurysms. Histologic evaluation showed progressive thrombus organization within aneurysm lumen from one to 12 months. These results indicated that the WEB II device can achieve high rates of aneurysm occlusion over time in experimental aneurysms.
Histopathological findings following pipeline embolization in a human cerebral aneurysm at the basilar tip
Kelly, Michael , Kadirvel, Ramanathan , Kallmes, David F. , Dai, Daying , Kallmes, David, Ding, Yonghong

Interventional Neuroradiology | February 3, 2016 | Volume: 22 | Issue: 2 | Pages: 153-157

10.1177/1591019915622165 Get It

We report histopathological findings from a human cerebral aneurysm following treatment with a flow diverter. A 75-year-old male underwent flow diversion treatment (Pipeline Embolization Device (PED)) and coil embolization for treatment of an aneurysm at the basilar tip. At four months, angiography showed complete aneurysm occlusion; at 12 months angiography demonstrated that the aneurysm had reopened. The patient expired from brainstem compression. The aneurysm cavity was primarily filled with unorganized thrombus. Thick, interrupted neointima crossed the neck interface indicating blood flow into aneurysm through small channels. Along the parent artery the PED was covered by neointima having a measured thickness of 0.19 ± 0.01 mm; the maximal stenosis of the proximal parent artery was 27%. The perforating arteries that were crossed by the PED remained patent. Findings in this human case are similar to those in the elastase-induced aneurysms in rabbits.
From bench to bedside: utility of the rabbit elastase aneurysm model in preclinical studies of intracranial aneurysm treatment
Brinjikji, Waleed , Ding, Yong Hong, Kallmes, David F. , Kadirvel, Ramanathan , Ding, Yong H, Ding, Yonghong

Journal of NeuroInterventional Surgery | April 22, 2015 | Volume: 8 | Issue: 5 | Pages: 521-525

10.1136/neurintsurg-2015-011704 Get It

Preclinical studies are important in helping practitioners and device developers improve techniques and tools for endovascular treatment of intracranial aneurysms. Thus an understanding of the major animal models used in such studies is important. The New Zealand rabbit elastase induced arterial aneurysm of the common carotid artery is one of the most commonly used models in testing the safety and efficacy of new endovascular devices. In this review we discuss: (1) the various techniques used to create the aneurysm, (2) complications of aneurysm creation, (3) natural history of the arterial aneurysm, (4) histopathologic and hemodynamic features of the aneurysm, (5) devices tested using this model, and (6) weaknesses of the model. We demonstrate how preclinical studies using this model are applied in the treatment of intracranial aneurysms in humans. The model has similar hemodynamic, morphological, and histologic characteristics to human aneurysms, and demonstrates similar healing responses to coiling as human aneurysms. Despite these strengths, however, the model does have many weaknesses, including the fact that the model does not emulate the complex inflammatory processes affecting growing and ruptured aneurysms. Furthermore, the extracranial location of the model affects its ability to be used in preclinical safety assessments of new devices. We conclude that the rabbit elastase model has characteristics that make it a simple and effective model for preclinical studies on the endovascular treatment of intracranial aneurysms, but further work is needed to develop aneurysm models that simulate the histopathologic and morphologic characteristics of growing and ruptured aneurysms.
Characterizing patterns of endothelialization following coil embolization: a whole-mount, dual immunostaining approach
Ding, Yong-Hong, Rezek, Issa, Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Ding, Yonghong

Journal of NeuroInterventional Surgery | February 2, 2015 | Volume: 8 | Issue: 4 | Pages: 402-406

10.1136/neurintsurg-2014-011513 Get It

Background The extent, rate, and source of endothelialization following coil embolization of saccular aneurysms remains poorly understood. We performed a whole tissue mount, dual immunohistochemical analysis of experimental aneurysms to characterize the state of endothelialization over time after platinum coil embolization. Method and material Elastase-induced rabbit aneurysms were created and treated with bare platinum coils. Samples were harvested at 4 and 8 weeks (n=6 for each). En face whole tissue mount staining with antibodies to CD31 and α-smooth muscle actin was used to identify endothelial cells and smooth muscle cells, respectively. Sytox green stain was used to demonstrate nuclear morphology for identification of inflammatory cells. The extent of endothelialization was measured in relation to the aneurysm neck–parent artery interface. Results At 4 weeks after coil embolization, very localized membranous tissue and neoendothelial cells were detected on the coil loops immediately adjacent to the parent artery–neck interface, but the remainder of the coil loops remained devoid of endothelial cells. At 8 weeks neoendothelial cells were more confluent over the coils than at 4 weeks, and extended up to 900 µm from the parent artery–neck interface. However, the surfaces of the coils farther away than this region harbored no endothelial cells. Scattered inflammatory cells, including neutrophils and monocytes, were seen on the coil surface at the neck central area, where the coil surface was bare at the 4 and 8 weeks’ follow-up. Conclusions Platinum coil embolization supports gradual but limited endothelialization, where endothelial cells migrate directly from the adjacent parent artery.
Gene expression comparison of flow diversion and coiling in an experimental aneurysm model
Puffer, Cole, Ding, Yong-Hong, Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Kallmes, David, Ding, Yonghong , Cebral, Juan R.

Journal of NeuroInterventional Surgery | October 20, 2014 | Volume: 7 | Issue: 12 | Pages: 926-930

10.1136/neurintsurg-2014-011452 Get It

Background and purpose Mechanisms of both healing and complications, including spontaneous aneurysm rupture, remain unclear following flow diverter treatment. The aim of this study was to compare gene expression of various key molecules involved in the healing of aneurysms, between aneurysms treated with microcoils and flow diverters. Methods Saccular aneurysms were created in rabbits. Aneurysms were treated with coils (n=6) or flow diverters (n=6). Aneurysms were harvested at 4 weeks following treatment and used for gene expression and zymography experiments. Genes with a fold change of 1.2 or more were considered upregulated whereas those with a fold change of 0.8 or less were considered downregulated. Results All coil embolized aneurysms were completely occluded at follow-up. Two aneurysms were occluded and the remaining four samples were incompletely occluded in the flow diverter treated group. The following genes were expressed at lower levels in the flow diverter group compared with the coiled aneurysm group: proteinases (matrix metalloproteinases 2 and 9), cellular markers (endothelial nitric oxide synthase and smooth muscle actin), and structural proteins (collagens and fibronectin). Genes related to inflammation (tumor necrosis factor α and monocyte chemoattractant protein 1) were upregulated in flow diverter treated aneurysms compared with coil embolized aneurysms. Notably, the enzymatic activity of active matrix metalloproteinase 9 was high in aneurysms treated with flow diverters. Conclusions Our findings may provide improved understanding of rupture risk and healing following aneurysm treatment and inform development of therapies aimed at lowering rupture risk and accelerating healing.