Back to Authors

Murray, David

https://orcid.org/0000-0003-1720-335X

Mayo Clinic

Mayo Clinic

Citations 115

Monitoring M-Proteins in Patients with Multiple Myeloma Using Heavy-Chain Variable Region Clonotypic Peptides and LC–MS/MS
Barnidge, David R. , Tschumper, Renee C. , Theis, Jason D. , Snyder, Melissa R., Jelinek, Diane F., Katzmann, Jerry A., Dispenzieri, Angela , Murray, David , Snyder, Melissa R., Dispenzieri, Angela

Journal of Proteome Research | February 20, 2014 | Volume: 13 | Issue: 4 | Pages: 1905-1910

10.1021/pr5000544 Get It

Using Mass Spectrometry to Monitor Monoclonal Immunoglobulins in Patients with a Monoclonal Gammopathy
Barnidge, David R. , Dasari, Surendra , Botz, Chad M. , Murray, Danelle H., Murray, Danelle H., Katzmann, Jerry A., Dispenzieri, Angela , Murray, David , Murray, Danelle H., Snyder, Michael , Dispenzieri, Angela

Journal of Proteome Research | January 27, 2014 | Volume: 13 | Issue: 3 | Pages: 1419-1427

10.1021/pr400985k Get It

Laboratory Persistence and Clinical Progression of Small Monoclonal Abnormalities
Murray, David , Seningen, Justin L., Dispenzieri, Angela , Snyder, Melissa R., Kyle, Robert A. , Rajkumar, S. Vincent , Katzmann, Jerry A., Snyder, Melissa R., Rajkumar, S Vincent , Dispenzieri, Angela

American Journal of Clinical Pathology | September 24, 2012 | Volume: 138 | Issue: 4 | Pages: 609-613

10.1309/ajcpt6owwmhita1y Get It

A 71-Year-Old Woman with Multiple Myeloma Status after Stem Cell Transplantation
Zeldenrust, Steven R., Murray, David , Katzmann, Jerry A., Donato, Leslie J.

Clinical Chemistry | November 28, 2011 | Volume: 57 | Issue: 12 | Pages: 1645-1648

10.1373/clinchem.2011.163766 Get It

Quantitation of Serum Monoclonal Proteins: Relationship between Agarose Gel Electrophoresis and Immunonephelometry
Murray, David , Ryu, Euijung , Snyder, Melissa R, Katzmann, Jerry A., Snyder, Melissa R

Clinical Chemistry | June 11, 2009 | Volume: 55 | Issue: 8 | Pages: 1523-1529

10.1373/clinchem.2009.124461 Get It

Abstract Background: Previous comparisons of monoclonal protein quantification identified a bias between serum protein electrophoresis (SPEP) and immunonephelometry (NEPH). Methods: We reviewed data from 2845 patients in whom a single sample provided a γ fraction M-spike by SPEP, a heavy chain isotype by immunofixation electrophoresis (IFE), and an Ig quantification by NEPH. We examined the relationship between SPEP and NEPH. Selected sera with high monoclonal protein concentrations were diluted and reassessed. Results: For all isotypes, the relationship between SPEP and NEPH was best fitted with cubic curves. We determined the concentrations of each isotype that fitted a linear relationship. IgA had the best correspondence (slope 0.92, 95% CI 0.87–1.02), whereas IgM demonstrated a systematic bias of higher values by NEPH (slope 1.80, 95% CI 1.68–1.92). IgG demonstrated a nonlinear relationship between SPEP and NEPH, with a linear region <19.2 g/L having a slope of 0.83 (95% CI 0.79–0.89) and a second linear region having a slope of 1.47 (95% CI 1.39–1.53) at higher concentrations. Dilutions of high-concentration IgG monoclonal proteins were linear by NEPH and nonlinear by SPEP. Conclusions: There are systematic differences in the quantification of monoclonal IgM and IgG by SPEP and NEPH. The bias in IgM is from NEPH overestimation. The nonlinearity of SPEP at high monoclonal IgG concentrations may obscure changes in plasma cell populations. Clinicians should be made aware of the biases and nonlinearity in these tests to make proper conclusions regarding treatment response.