Back to Authors

Garza‐Ramos, Cynthia De la

https://orcid.org/0000-0002-6476-0397

Mayo Clinic

Mayo Clinic in Florida

Citations 11

Consortium on Bridging Radiation Segmentectomy (COBRAS): A Multicenter Study of Complete Pathologic Necrosis in Hepatocellular Carcinoma
Berman, Zachary T. , Garza‐Ramos, Cynthia De la , Montazeri, Seyed Ali , Malone, Christopher D. , Sandow, Tyler, Gimenez, Juan , Young, Shamar, Fidelman, MD Nicholas, Pianka, Kurt, Sher, Alex, Vakil, Parmede , Wang, Melinda , Abounorinejad, Faraz, Johnson, Guy E. , Padia, Siddarth, Kim, Edward , Toskich, Beau B. , De la Garza-Ramos, Cynthia , Montazeri, S Ali , Fidelman, Nicholas , Pianka, Kurt T , Alamuri, Tharun , Chan, Shin Mei , Wang, Melinda , Abounorinejad, Faraz , Padia, Siddarth A , Kim, Edward , Toskich, Beau , Berman, Zachary T. , Malone, Christopher D , Sandow, Tyler Allan , Sher, Alex , Chan, Shin Mei , Som, Avik

Radiology | May 5, 2026 | Volume: 319 | Issue: 2 | Pages: No page available

10.1148/radiol.251923 Get It

Among patients with treatment-naive hepatocellular carcinoma, glass microsphere radiation segmentectomy before liver transplant achieved high rates of complete pathologic necrosis, which was positively associated with the number of optimized treatment parameter thresholds.
Case Report: durable response to pulsed electric field ablation in combination with immune checkpoint inhibitors in HER2-low breast cancer through activation of interferon signaling
Liu, Yi, Garza-Ramos, Cynthia C. De la, Gabriel, Emmanuel, Toskich, Beau, Thompson, E. Aubrey, Chumsri, Saranya , Gabriel, Emmanuel , Gabriel, Emmanuel M , Garza‐Ramos, Cynthia De la , Gabriel, Emmanuel, Nassar, Aziza , Thompson, E. Aubrey

Frontiers in Oncology | April 10, 2026 | Volume: 16 | Issue: No issue available | Pages: No page available

10.3389/fonc.2026.1681010 Get It

Pulsed Electric Field (PEF) ablation is a non-thermal cancer treatment that disrupts tumor cell membranes while preserving the immune microenvironment and promoting immunogenic cell death. We present a case of a patient with metastatic hormone receptor-positive, HER2-low breast cancer who achieved a durable clinical response after PEF in combination with an immune checkpoint inhibitor (pembrolizumab). The patient remained off systemic therapy for 14 months without disease progression. Single-cell spatial molecular imaging (SMI) and gene set enrichment analysis (GSEA) were performed to evaluate immune microenvironment changes pre- and post-PEF treatment. Spatial transcriptomics of the tumor cell compartment revealed a post-PEF enrichment of immune-related pathways, including interferon alpha/beta and gamma signaling and MHC class I antigen processing and presentation, alongside increased infiltration of immune cells: CD8+ T cells, plasmablasts, and monocytes within the tumor neighborhood. This hypothesis-generating case suggests PEF’s potential to reshape the tumor-immune microenvironment when combined with immune checkpoint blockade, warranting further studies on its role in combination immunotherapy strategies.
Letter to the Editor: Reply to “Population Screening for Cirrhosis” by Thiele et al, describing the Florida Healthy Liver Program
Ryland, Kristen, Harnois, Denise M. , Strong, Cyneetha, Whiddon, George, Mulrooney, Christopher, Littles, Alma B., Toskich, Beau , Ryland, Kristen L, Garza‐Ramos, Cynthia De la , Patel, Tushar , Mulrooney, Christopher

Hepatology Communications | June 9, 2025 | Volume: 9 | Issue: 7 | Pages: No page available

10.1097/hc9.0000000000000713 Get It

Pearls and Pitfalls of First-Trimester US Screening and Prenatal Testing: A Pictorial Review
Packard, Annie T. , Clingan, M. Jennings , Strachowski, Lori M. , Rose, Carl H., Trinidad, Mari Charisse, Amiraian, Dana , Rodgers, Shuchi K. , Caserta, Melanie P. , Clingan, Mary Jennings , Trinidad, Mari Charisse B, Amiraian, Dana , Rodgers, Shuchi K , Caserta, Melanie P , Strachowski, Lori , Garza‐Ramos, Cynthia De la

RadioGraphics | May 15, 2025 | Volume: 45 | Issue: 6 | Pages: No page available

10.1148/rg.240184 Get It

First-trimester US is imperative in evaluation of early pregnancy, since understanding of first-trimester anatomy and genetic testing allows early detection of structural and chromosomal abnormalities.
Can we screen opportunistically for low bone mineral density using CT scans of the shoulder and artificial intelligence?
Sebro, Ronnie , Garza‐Ramos, Cynthia De la , De la Garza-Ramos, Cynthia

British Journal of Radiology | June 5, 2024 | Volume: 97 | Issue: 1160 | Pages: 1450-1460

10.1093/bjr/tqae109 Get It

Abstract Objective To evaluate whether the CT attenuation of bones seen on shoulder CT scans could be used to predict low bone mineral density (BMD) (osteopenia/osteoporosis), and to compare the performance of two machine learning models to predict low BMD. Methods In this study, we evaluated 194 patients aged 50 years or greater (69.2 ± 9.1 years; 170 females) who underwent unenhanced shoulder CT scans and dual-energy X-ray absorptiometry within 1 year of each other between January 1, 2010, and December 31, 2021. The CT attenuation of the humerus, glenoid, coracoid, acromion, clavicle, first, second, and third ribs was obtained using 3D-Slicer. Support vector machines (SVMs) and k-nearest neighbours (kNN) were used to predict low BMD. DeLong test was used to compare the areas under the curve (AUCs). Results A CT attenuation of 195.4 Hounsfield Units of the clavicle had a sensitivity of 0.577, specificity of 0.781, and AUC of 0.701 to predict low BMD. In the test dataset, the SVM had sensitivity of 0.686, specificity of 1.00, and AUC of 0.857, while the kNN model had sensitivity of 0.966, specificity of 0.200, and AUC of 0.583. The SVM was superior to the CT attenuation of the clavicle (P = .003) but not better than the kNN model (P = .098). Conclusion The CT attenuation of the clavicle was best for predicting low BMD; however, a multivariable SVM was superior for predicting low BMD. Advances in knowledge SVM utilizing the CT attenuations at many sites was best for predicting low BMD.
Radiation Segmentectomy for the Treatment of Hepatocellular Carcinoma: A Practical Review of Evidence
Mourad, Sophia N., Toskich, Beau B. , Garza‐Ramos, Cynthia De la

Cancers | February 6, 2024 | Volume: 16 | Issue: 3 | Pages: 669

10.3390/cancers16030669 Get It

Radiation segmentectomy is a versatile, safe, and effective ablative therapy for early-stage hepatocellular carcinoma. Advances in radiation segmentectomy patient selection, procedural technique, and dosimetry have positioned this modality as a curative-intent and guideline-supported treatment for patients with solitary HCC. This review describes key radiation segmentectomy concepts and summarizes the existing literary knowledgebase.
Nononcologic Embolization
Salei, Aliaksei , Caridi, T. , Garza‐Ramos, Cynthia De la

Seminars in Interventional Radiology | November 17, 2022 | Volume: 39 | Issue: 04 | Pages: 416-420

10.1055/s-0042-1758077 Get It

AbstractThe scope of conditions managed by embolization, which was initially used for the treatment of hemorrhage and vascular malformations, is constantly expanding. Apart from oncologic indications, embolization is used to treat a wide range of benign pathology, including uterine fibroids and benign prostatic hyperplasia. While various particulate embolic agents are successfully used for benign embolization, there is growing evidence that unique properties of these may result in different outcomes. This article reviews available evidence comparing various particles used for uterine fibroid embolization and prostate artery embolization. In addition, we provide an overview of periprocedural pharmacology and protocols facilitating same-day discharge for these interventions.
Correction: Sebro, R.; De la Garza-Ramos, C. Machine Learning for Opportunistic Screening for Osteoporosis from CT Scans of the Wrist and Forearm. Diagnostics 2022, 12, 691
Sebro, Ronnie , Garza‐Ramos, Cynthia De la , De la Garza-Ramos, Cynthia

Diagnostics | October 31, 2022 | Volume: 12 | Issue: 11 | Pages: 2635

10.3390/diagnostics12112635 Get It

In the original publication [...]
Statistically based nomograms for the minimal needle length required to achieve intra‐articular fluoroscopic‐guided injections of the shoulder, hip, and knee
Sebro, Ronnie , Garza‐Ramos, Cynthia De la , De la Garza-Ramos, Cynthia

PM&R | June 16, 2022 | Volume: 15 | Issue: 7 | Pages: 853-864

10.1002/pmrj.12864 Get It

AbstractBackgroundImage‐guided intra‐articular injections are commonly performed to reduce pain in patients with arthritis or other joint‐related pathology. Utilizing a needle length that is too short could lead to increased patient discomfort, increased procedural time, and extra‐articular injections.ObjectiveTo predict the minimum needle length required for fluoroscopic‐guided intra‐articular injections of the hips, knees, and shoulders based on patient age, gender, height and weight, or body mass index (BMI) and to evaluate whether this varies by gender.Study DesignCross‐sectional study.SettingTertiary care academic center.Participants600 consecutive patients with available magnetic resonance imaging (MRI) of the hips, knees, and shoulders (100 males and 100 females for each joint).MethodsThe distance from the skin to the joint (glenohumeral, hip and knee) and the thickness of the subcutaneous fat pad (distance from the skin to the muscle) along the injection path were measured. Multivariable linear ridge regression with 10‐fold cross‐validation was used to predict the distance from the skin to the hip, knee, and glenohumeral joints using age, gender, weight, and height or using age, gender, and BMI.ResultsThe data show that the subcutaneous fat thickness and the distance from the skin to all joints increase with weight (p < .001) and BMI (p < .001). Subcutaneous fat pads around the anterior shoulder (p < .02) and knee (<.001) are thicker in women than in men.ConclusionsPatient habitus, in particular weight and BMI, are strong predictors of the thickness of the subcutaneous fat pads and consequently strong predictors of the distance from the skin to the joint. Subcutaneous fat pad thickness around the shoulders and knees varies by gender. Nomograms showing the minimal needle length required to achieve intra‐articular injections of the hip, knee and glenohumeral joints are presented.
Machine Learning for Opportunistic Screening for Osteoporosis from CT Scans of the Wrist and Forearm
Sebro, Ronnie , Garza‐Ramos, Cynthia De la , De la Garza-Ramos, Cynthia

Diagnostics | March 11, 2022 | Volume: 12 | Issue: 3 | Pages: 691

10.3390/diagnostics12030691 Get It

Background: We investigated whether opportunistic screening for osteoporosis can be done from computed tomography (CT) scans of the wrist/forearm using machine learning. Methods: A retrospective study of 196 patients aged 50 years or greater who underwent CT scans of the wrist/forearm and dual-energy X-ray absorptiometry (DEXA) scans within 12 months of each other was performed. Volumetric segmentation of the forearm, carpal, and metacarpal bones was performed to obtain the mean CT attenuation of each bone. The correlations of the CT attenuations of each of the wrist/forearm bones and their correlations to the DEXA measurements were calculated. The study was divided into training/validation (n = 96) and test (n = 100) datasets. The performance of multivariable support vector machines (SVMs) was evaluated in the test dataset and compared to the CT attenuation of the distal third of the radial shaft (radius 33%). Results: There were positive correlations between each of the CT attenuations of the wrist/forearm bones, and with DEXA measurements. A threshold hamate CT attenuation of 170.2 Hounsfield units had a sensitivity of 69.2% and a specificity of 77.1% for identifying patients with osteoporosis. The radial-basis-function (RBF) kernel SVM (AUC = 0.818) was the best for predicting osteoporosis with a higher AUC than other models and better than the radius 33% (AUC = 0.576) (p = 0.020). Conclusions: Opportunistic screening for osteoporosis could be performed using CT scans of the wrist/forearm. Multivariable machine learning techniques, such as SVM with RBF kernels, that use data from multiple bones were more accurate than using the CT attenuation of a single bone.