Back to Authors

Craici, Iasmina

0009-0004-6739-4531

Mayo Clinic

Mayo Clinic

Citations 49

Outcomes of Delivery Hospitalizations Among Pregnant Women with Kidney Transplant in the United States
Kattah, Andrea G. , Craici, Iasmina , Chewcharat, Api , Thongprayoon, Charat , Cheungpasitporn, Wisit , Boonpheng, Boonphiphop , Suarez, Maria Lourdes Gonzalez , Garovic, Vesna D.

Journal of the American Society of Nephrology | May 17, 2024 | Volume: 31 | Issue: 10S | Pages: 790-790

10.1681/asn.20203110s1790a Get It

Outcomes of peritoneal dialysis in cirrhosis: A systematic review and meta-analysis
Miao, Jing , Leelaviwat, Natnicha , Thongpiya, Jerapas , Craici, Iasmina , Cheungpasitporn, Wisit , Craici, Iasmina M, Cheungpasitporn, Wisit , Miao, Jing , Mekraksakit, Poemlarp , Suppadungsuk, Supawadee , Thongprayoon, Charat , Qureshi, Fawad

Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis | May 17, 2024 | Volume: 45 | Issue: 2 | Pages: 93-105

10.1177/08968608241237401 Get It

Background: Cirrhosis and end-stage kidney disease (ESKD) are significant global health concerns, contributing to high mortality and morbidity. Haemodialysis (HD) is frequently used to treat ESKD in patients with cirrhosis. However, it often presents challenges such as haemodynamic instability during dialysis sessions, leading to less than optimal outcomes. Peritoneal dialysis (PD), while less commonly used in cirrhotic patients, raises concerns about the risks of peritonitis and mortality. Our systematic review and meta-analysis aimed to assess outcomes in PD patients with cirrhosis. Methods: We executed a comprehensive search in Ovid MEDLINE, EMBASE and Cochrane databases up to 25 September 2023. The search focused on identifying studies examining mortality and other clinical outcomes in ESKD patients with cirrhosis receiving PD or HD. In addition, we sought studies comparing PD outcomes in cirrhosis patients to those without cirrhosis. Data from each study were aggregated using a random-effects model and the inverse-variance method. Results: Our meta-analysis included a total of 13 studies with 15,089 patients. Seven studies compared ESKD patients on PD with liver cirrhosis (2753 patients) against non-cirrhosis patients (9579 patients). The other six studies provided data on PD (824 patients) versus HD (1943 patients) in patients with cirrhosis and ESKD. The analysis revealed no significant difference in mortality between PD and HD in ESKD patients with cirrhosis (pooled odds ratio (OR) of 0.77; 95% confidence interval (CI), 0.53–1.14). In PD patients with cirrhosis, the pooled OR for peritonitis compared to non-cirrhosis patients was 1.10 (95% CI: 1.03–1.18). The pooled ORs for hernia and chronic hypotension in cirrhosis patients compared to non-cirrhosis controls were 2.48 (95% CI: 0.08–73.04) and 17.50 (95% CI: 1.90–161.11), respectively. The pooled OR for transitioning from PD to HD among cirrhotic patients was 1.71 (95% CI: 0.76–3.85). Mortality in cirrhosis patients on PD was comparable to non-cirrhosis controls, with a pooled OR of 1.05 (95% CI: 0.53–2.10). Conclusions: Our meta-analysis demonstrates that PD provides comparable mortality outcomes to HD in ESKD patients with cirrhosis. In addition, the presence of cirrhosis does not significantly elevate the risk of mortality among patients undergoing PD. While there is a higher incidence of chronic hypotension and a slightly increased risk of peritonitis in cirrhosis patients on PD compared to those without cirrhosis, the risks of hernia and the need to transition from PD to HD are comparable between both groups. These findings suggest PD as a viable and effective treatment option for ESKD patients with cirrhosis.
Evaluating ChatGPT's efficacy in assessing the safety of non-prescription medications and supplements in patients with kidney disease
Sheikh, M. Salman , Frazee, Erin N. , Miao, Jing , Thongprayoon, Charat , Gregoire, James R., Dreesman, Benjamin , Erickson, Stephen B., Craici, Iasmina , Cheungpasitporn, Wisit , Sheikh, Mohammad S , Craici, Iasmina M, Cheungpasitporn, Wisit , Thongprayoon, Charat , Miao, Jing

DIGITAL HEALTH | April 17, 2024 | Volume: 10 | Issue: No issue available | Pages: No page available

10.1177/20552076241248082 Get It

Background This study investigated the efficacy of ChatGPT-3.5 and ChatGPT-4 in assessing drug safety for patients with kidney diseases, comparing their performance to Micromedex, a well-established drug information source. Despite the perception of non-prescription medications and supplements as safe, risks exist, especially for those with kidney issues. The study's goal was to evaluate ChatGPT's versions for their potential in clinical decision-making regarding kidney disease patients. Method The research involved analyzing 124 common non-prescription medications and supplements using ChatGPT-3.5 and ChatGPT-4 with queries about their safety for people with kidney disease. The AI responses were categorized as “generally safe,” “potentially harmful,” or “unknown toxicity.” Simultaneously, these medications and supplements were assessed in Micromedex using similar categories, allowing for a comparison of the concordance between the two resources. Results Micromedex identified 85 (68.5%) medications as generally safe, 35 (28.2%) as potentially harmful, and 4 (3.2%) of unknown toxicity. ChatGPT-3.5 identified 89 (71.8%) as generally safe, 11 (8.9%) as potentially harmful, and 24 (19.3%) of unknown toxicity. GPT-4 identified 82 (66.1%) as generally safe, 29 (23.4%) as potentially harmful, and 13 (10.5%) of unknown toxicity. The overall agreement between Micromedex and ChatGPT-3.5 was 64.5% and ChatGPT-4 demonstrated a higher agreement at 81.4%. Notably, ChatGPT-3.5's suboptimal performance was primarily influenced by a lower concordance rate among supplements, standing at 60.3%. This discrepancy could be attributed to the limited data on supplements within ChatGPT-3.5, with supplements constituting 80% of medications identified as unknown. Conclusion ChatGPT's capabilities in evaluating the safety of non-prescription drugs and supplements for kidney disease patients are modest compared to established drug information resources. Neither ChatGPT-3.5 nor ChatGPT-4 can be currently recommended as reliable drug information sources for this demographic. The results highlight the need for further improvements in the model's accuracy and reliability in the medical domain.
Rituximab or cyclosporine A for the treatment of membranous nephropathy: economic evaluation of the MENTOR trial
So, Helen , Fervenza, Fernando C. , Cattran, Daniel C., Barbour, Sean J. , Investigators, MENTOR Study, Cattran, D C, Appel, Gerald B., Gipson, D, Erickson, Stephen B., Radhakrishnan, Jay, Bomback, A.S., Hogan, Jonathan, Arora, Neha , Nargund, Preeti, Alvarado, Anthony, Hebert, Lee A., Aslam, Nabeel , Porter, Ivan E. , Gipson, Patrick E., Plattner, Brandon L. , Gipson, D, Mariani, Laura , Garg, Pranay, Jefferson, J. Ashley , Nelson, Peter J. , Yarlagadda, Sri G. , Simon, James F. , Gebreselassie, Surafel , Blumenthal, Stanley A., Thomas, L, Cohen, Irvin M., Keddis, Mira T. , Sussman, Andrew L. , Thajudeen, Bijin , Fülöp, Tibor , Craici, Iasmina , Wagner, Steven J., DREISBACH, A, Monga, D., Green, D, Nayer, Ali, Thomas, D. B., Cattran, D C, Reich, Heather N. , Barbour, S. Lee , Philibert, D., Mac‐Way, Fabrice , Desmeules, Simon, Ankawi, Ghada , Sethi, Sanjeev , Ávila-Casado, Carmen , Beanlands, Heather , Fervenza, Fernando C , Kadatz, Matthew , Klarenbach, Scott W , Investigators, MENTOR Study, Cattran, D C, Gipson, D, Kretzler, Matthias , Rovin, Brad H. , Lieske, John C. , Leung, Nelson , Canetta, Pietro A. , Ahn, W, Lafayette, Richard , Arora, N, Parikh, Samir M. , Plattner, B, Gipson, D, Rao, P, Sedor, John R. , O'Toole, J, McCarthy, E, Jain, Namrata Gargee , Rizk, D, Blumenthal, S, Beara‐Lasić, Lada , Zhdanova, Olga A. , Thomas, L, Sussman, A, Juncos, Luis A. , Fulop, T, Monga, D, Mattiazzi, Adela D. , Thomas, D, Barisoni, Laura , Li, T, Vijayan, Anitha , Cattran, D C, Hladunewich, Michelle , Barbour, S, Levin, Adeera , Philibert, D

Nephrology Dialysis Transplantation | April 13, 2024 | Volume: 39 | Issue: 12 | Pages: 2058-2066

10.1093/ndt/gfae084 Get It

ABSTRACT Background and hypothesis The MENTOR trial (MEmbranous Nephropathy Trial Of Rituximab) showed that rituximab was noninferior to cyclosporine in inducing complete or partial remission of proteinuria and was superior in maintaining proteinuria remission. However, the cost of rituximab may prohibit first-line use for some patients and health-care payers. Methods A Markov model was used to determine the incremental cost-effectiveness ratio (ICER) of rituximab compared with cyclosporine for the treatment membranous nephropathy from the perspective of a health-care payer with a lifetime time horizon. The model was informed by data from the MENTOR trial where possible; additional parameters including cost and utility inputs were obtained from the literature. Sensitivity analyses were performed to evaluate the impact of reduced-cost biosimilar rituximab. Results Rituximab for the treatment of membranous nephropathy was cost effective (assuming a willingness-to-pay threshold of $50 000 per quality-adjusted life year (QALY) gained; in $US 2021) compared with cyclosporine, with an ICER of $8373/QALY over a lifetime time horizon. The incremental cost of rituximab therapy was $28 007 with an additional 3.34 QALYs compared with cyclosporine. Lower cost of rituximab biosimilars resulted in a more favorable ICER, and in some cases resulted in rituximab being dominant (lower cost and great benefit) compared to cyclosporine. Conclusions Despite the greater cost of rituximab, it may be a cost-effective option for the treatment of membranous nephropathy when compared with cyclosporine. The cost-effectiveness of rituximab is further improved with the use of less expensive biosimilars.
Perspectives on AI-based recommendations for mask-wearing and COVID-19 vaccination for transplant recipients in the post-COVID-19 era
Valencia, Oscar A. Garcia , Miao, Jing , Craici, Iasmina , Cheungpasitporn, Wisit , Garcia Valencia, Oscar A, Craici, Iasmina M, Cheungpasitporn, Wisit , Garcia-Valencia, Oscar , Miao, Jing , Thongprayoon, Charat , Bruminhent, Jackrapong

Renal Failure | April 8, 2024 | Volume: 46 | Issue: 1 | Pages: No page available

10.1080/0886022x.2024.2337291 Get It

Personalized Medicine Transformed: ChatGPT’s Contribution to Continuous Renal Replacement Therapy Alarm Management in Intensive Care Units
Sheikh, M. Salman , Qureshi, Fawad , Kashani, Kianoush , Miao, Jing , Craici, Iasmina , Cheungpasitporn, Wisit , Sheikh, Mohammad S , Qureshi, Fawad , Kashani, Kianoush B , Miao, Jing , Craici, Iasmina M, Cheungpasitporn, Wisit , Thongprayoon, Charat , Suppadungsuk, Supawadee

Journal of Personalized Medicine | February 22, 2024 | Volume: 14 | Issue: 3 | Pages: 233

10.3390/jpm14030233 Get It

The accurate interpretation of CRRT machine alarms is crucial in the intensive care setting. ChatGPT, with its advanced natural language processing capabilities, has emerged as a tool that is evolving and advancing in its ability to assist with healthcare information. This study is designed to evaluate the accuracy of the ChatGPT-3.5 and ChatGPT-4 models in addressing queries related to CRRT alarm troubleshooting. This study consisted of two rounds of ChatGPT-3.5 and ChatGPT-4 responses to address 50 CRRT machine alarm questions that were carefully selected by two nephrologists in intensive care. Accuracy was determined by comparing the model responses to predetermined answer keys provided by critical care nephrologists, and consistency was determined by comparing outcomes across the two rounds. The accuracy rate of ChatGPT-3.5 was 86% and 84%, while the accuracy rate of ChatGPT-4 was 90% and 94% in the first and second rounds, respectively. The agreement between the first and second rounds of ChatGPT-3.5 was 84% with a Kappa statistic of 0.78, while the agreement of ChatGPT-4 was 92% with a Kappa statistic of 0.88. Although ChatGPT-4 tended to provide more accurate and consistent responses than ChatGPT-3.5, there was no statistically significant difference between the accuracy and agreement rate between ChatGPT-3.5 and -4. ChatGPT-4 had higher accuracy and consistency but did not achieve statistical significance. While these findings are encouraging, there is still potential for further development to achieve even greater reliability. This advancement is essential for ensuring the highest-quality patient care and safety standards in managing CRRT machine-related issues.
Safety and Efficacy of GLP-1 Receptor Agonists in Type 2 Diabetes Mellitus with Advanced and End-Stage Kidney Disease: A Systematic Review and Meta-Analysis
Krisanapan, Pajaree , Sanpawithayakul, Kanokporn , Miao, Jing , Mao, Michael A. , Tangpanithandee, Supawit , Craici, Iasmina , Cheungpasitporn, Wisit , Miao, Jing , Mao, Michael A , Craici, Iasmina M, Cheungpasitporn, Wisit , Tangpanithandee, Supawit , Krisanapan, Pajaree , Pattharanitima, Pattharawin , Thongprayoon, Charat , Suppadungsuk, Supawadee

Diseases | January 2, 2024 | Volume: 12 | Issue: 1 | Pages: 14

10.3390/diseases12010014 Get It

Background and Objectives: Limited evidence exists regarding the safety and efficacy of glucagon-like peptide-1 receptor agonists (GLP-1RAs) in type 2 diabetes mellitus (T2DM) patients with advanced chronic kidney disease (CKD) or end-stage kidney disease (ESKD). Thus, we conducted a systematic review and meta-analysis to assess the safety and efficacy of GLP-1RAs in T2DM patients with advanced CKD and ESKD. Materials and Methods: We performed a systematic literature search in MEDLINE, EMBASE, and Cochrane database until 25 October 2023. Included were clinical trials and cohort studies reporting outcomes of GLP-1RAs in adult patients with T2DM and advanced CKD. Outcome measures encompassed mortality, cardiovascular parameters, blood glucose, and weight. Safety was assessed for adverse events. The differences in effects were expressed as odds ratios with 95% confidence intervals (CIs) for dichotomous outcomes and the weighted mean difference or standardized mean difference (SMD) with 95% confidence intervals for continuous outcomes. The Risk of Bias In Non-randomized Studies—of Interventions (ROBIN-I) tool was used in cohort and non-randomized controlled studies, and the Cochrane Risk of Bias (RoB 2) tool was used in randomized controlled trials (RCTs). The review protocol was registered in the International Prospective Register of Systematic Reviews (CRD 42023398452) and received no external funding. Results: Eight studies (five trials and three cohort studies) consisting of 27,639 patients were included in this meta-analysis. No difference was observed in one-year mortality. However, GLP-1RAs significantly reduced cardiothoracic ratio (SMD of −1.2%; 95% CI −2.0, −0.4) and pro-BNP (SMD −335.9 pmol/L; 95% CI −438.9, −232.8). There was no significant decrease in systolic blood pressure. Moreover, GLP-1RAs significantly reduced mean blood glucose (SMD −1.1 mg/dL; 95% CI −1.8, −0.3) and increased weight loss (SMD −2.2 kg; 95% CI −2.9, −1.5). In terms of safety, GLP-1RAs were associated with a 3.8- and 35.7-time higher risk of nausea and vomiting, respectively, but were not significantly associated with a higher risk of hypoglycemia. Conclusions: Despite the limited number of studies in each analysis, our study provides evidence supporting the safety and efficacy of GLP-1RAs among T2DM patients with advanced CKD and ESKD. While gastrointestinal side effects may occur, GLP-1RAs demonstrate significant improvements in blood glucose control, weight reduction, and potential benefit in cardiovascular outcomes.
Ethical Implications of Chatbot Utilization in Nephrology
Valencia, Oscar A. Garcia , Suppadungsuk, Supawadee , Miao, Jing , Tangpanithandee, Supawit , Craici, Iasmina , Cheungpasitporn, Wisit , Garcia-Valencia, Oscar , Miao, Jing , Tangpanithandee, Supawit , Craici, Iasmina M, Cheungpasitporn, Wisit , Suppadungsuk, Supawadee , Thongprayoon, Charat

Journal of Personalized Medicine | September 8, 2023 | Volume: 13 | Issue: 9 | Pages: 1363

10.3390/jpm13091363 Get It

This comprehensive critical review critically examines the ethical implications associated with integrating chatbots into nephrology, aiming to identify concerns, propose policies, and offer potential solutions. Acknowledging the transformative potential of chatbots in healthcare, responsible implementation guided by ethical considerations is of the utmost importance. The review underscores the significance of establishing robust guidelines for data collection, storage, and sharing to safeguard privacy and ensure data security. Future research should prioritize defining appropriate levels of data access, exploring anonymization techniques, and implementing encryption methods. Transparent data usage practices and obtaining informed consent are fundamental ethical considerations. Effective security measures, including encryption technologies and secure data transmission protocols, are indispensable for maintaining the confidentiality and integrity of patient data. To address potential biases and discrimination, the review suggests regular algorithm reviews, diversity strategies, and ongoing monitoring. Enhancing the clarity of chatbot capabilities, developing user-friendly interfaces, and establishing explicit consent procedures are essential for informed consent. Striking a balance between automation and human intervention is vital to preserve the doctor–patient relationship. Cultural sensitivity and multilingual support should be considered through chatbot training. To ensure ethical chatbot utilization in nephrology, it is imperative to prioritize the development of comprehensive ethical frameworks encompassing data handling, security, bias mitigation, informed consent, and collaboration. Continuous research and innovation in this field are crucial for maximizing the potential of chatbot technology and ultimately improving patient outcomes.
Safety and Efficacy of Vaptans in the Treatment of Hyponatremia from Syndrome of Inappropriate Antidiuretic Hormone Secretion (SIADH): A Systematic Review and Meta-Analysis
Krisanapan, Pajaree , Tangpanithandee, Supawit , Pattharanitima, Pattharawin , Kleindienst, Andrea , Miao, Jing , Craici, Iasmina , Mao, Michael A. , Cheungpasitporn, Wisit , Pattharanitima, Pattharawin , Kleindienst, Andrea , Miao, Jing , Craici, Iasmina M, Mao, Michael A , Cheungpasitporn, Wisit , Tangpanithandee, Supawit , Krisanapan, Pajaree , Thongprayoon, Charat

Journal of Clinical Medicine | August 24, 2023 | Volume: 12 | Issue: 17 | Pages: 5483

10.3390/jcm12175483 Get It

The utilization of vasopressin receptor antagonists, known as vaptans, in the management of hyponatremia among patients afflicted with the syndrome of inappropriate antidiuretic hormone (SIADH) remains a contentious subject. This meta-analysis aimed to evaluate the safety and efficacy of vaptans for treating chronic hyponatremia in adult SIADH patients. Clinical trials and observational studies were identified by a systematic search using MEDLINE, EMBASE, and Cochrane Database from inception through September 2022. The inclusion criteria were the studies that reported vaptans’ safety or efficacy outcomes compared to placebo or standard therapies. The study protocol was registered with the International Prospective Register of Systematic Reviews (PROSPERO; CRD 42022357307). Five studies were identified, comprising three RCTs and two cohort studies, enrolling a total of 1840 participants. Regarding short-term efficacy on days 4–5, vaptans exhibited a significant increase in serum sodium concentration from the baseline in comparison to the control group, with a weighted mean difference of 4.77 mmol/L (95% CI, 3.57, 5.96; I2 = 34%). In terms of safety outcomes, the pooled incidence rates of overcorrection were 13.1% (95% CI 4.3, 33.6; I2 = 92%) in the vaptans group and 3.3% (95% CI 1.6, 6.6; I2 = 27%) in the control group. Despite the higher correction rate linked to vaptans, with an OR of 5.72 (95% CI 3.38, 9.70; I2 = 0%), no cases of osmotic demyelination syndrome were observed. Our meta-analysis comprehensively summarizes the efficacy and effect size of vaptans in managing SIADH. While vaptans effectively raise the serum sodium concentration compared to placebo/fluid restriction, clinicians should exercise caution regarding the potential for overcorrection.
Characteristics of Kidney Transplant Recipients with Prolonged Pre-Transplant Dialysis Duration as Identified by Machine Learning Consensus Clustering: Pathway to Personalized Care
Tangpanithandee, Supawit , Jadlowiec, Caroline C. , Mao, Shennen A. , Mao, Michael A. , Vaitla, Pradeep , Acharya, Prakrati , Leeaphorn, Napat , Kaewput, Wisit , Pattharanitima, Pattharawin , Suppadungsuk, Supawadee , Krisanapan, Pajaree , Craici, Iasmina , Cheungpasitporn, Wisit , Tangpanithandee, Supawit , Jadlowiec, Caroline , Mao, Shennen A , Mao, Michael A , Kaewput, Wisit , Pattharanitima, Pattharawin , Suppadungsuk, Supawadee , Krisanapan, Pajaree , Craici, Iasmina M, Cheungpasitporn, Wisit , Thongprayoon, Charat , Nissaisorakarn, Pitchaphon , Cooper, Matthew

Journal of Personalized Medicine | August 21, 2023 | Volume: 13 | Issue: 8 | Pages: 1273

10.3390/jpm13081273 Get It

Longer pre-transplant dialysis duration is known to be associated with worse post-transplant outcomes. Our study aimed to cluster kidney transplant recipients with prolonged dialysis duration before transplant using an unsupervised machine learning approach to better assess heterogeneity within this cohort. We performed consensus cluster analysis based on recipient-, donor-, and transplant-related characteristics in 5092 kidney transplant recipients who had been on dialysis ≥ 10 years prior to transplant in the OPTN/UNOS database from 2010 to 2019. We characterized each assigned cluster and compared the posttransplant outcomes. Overall, the majority of patients with ≥10 years of dialysis duration were black (52%) or Hispanic (25%), with only a small number (17.6%) being moderately sensitized. Within this cohort, three clinically distinct clusters were identified. Cluster 1 patients were younger, non-diabetic and non-sensitized, had a lower body mass index (BMI) and received a kidney transplant from younger donors. Cluster 2 recipients were older, unsensitized and had a higher BMI; they received kidney transplant from older donors. Cluster 3 recipients were more likely to be female with a higher PRA. Compared to cluster 1, cluster 2 had lower 5-year death-censored graft (HR 1.40; 95% CI 1.16–1.71) and patient survival (HR 2.98; 95% CI 2.43–3.68). Clusters 1 and 3 had comparable death-censored graft and patient survival. Unsupervised machine learning was used to characterize kidney transplant recipients with prolonged pre-transplant dialysis into three clinically distinct clusters with variable but good post-transplant outcomes. Despite a dialysis duration ≥ 10 years, excellent outcomes were observed in most recipients, including those with moderate sensitization. A disproportionate number of minority recipients were observed within this cohort, suggesting multifactorial delays in accessing kidney transplantation.