Back to Authors

Washington, John A.

Mayo Clinic

Mayo Clinic

Citations 57

Microbiological Study of Streptococcal Bacteremia
Horstmeier, C D, Washington, John A.

Applied Microbiology | December 5, 2020 | Volume: 26 | Issue: 4 | Pages: 589-591

10.1128/am.26.4.589-591.1973 Get It

During a 2.5-year study, streptococci were isolated from 280 patients (19% of those with bacteremia). Of this number, 54 had group D streptococci (45 were enterococci), 218 had α- or γ-hemolytic nongroup D streptococci, and 49 had β-hemolytic streptococci.
Evaluation of Accuracy of Multitest Micromethod System for Identification of Enterobacteriaceae
Washington, John A., Yu, Pauline K. W., Martin, William J.

Applied Microbiology | December 5, 2020 | Volume: 22 | Issue: 3 | Pages: 267-269

10.1128/am.22.3.267-269.1971 Get It

The Analytab system of 20 biochemical tests for identification of Enterobacteriaceae was evaluated in parallel with conventional tests on 128 Enterobacteriaceae , 5 Aeromonas , and 1 Yersinia enterocolitica. The results of tests for H 2 S and indole production, citrate utilization, lysine and ornithine decarboxylase, arginine dihydrolase, nitrate reduction, β-galactosidase, and fermentation of arabinose, rhamnose, mannitol, and glucose showed almost complete agreement between the two systems. Eighty-eight per cent of Enterobacteriaceae were correctly speciated with the Analytab system; on repeat testing with heavier inocula of organisms failing to ferment glucose initially, the proportion of Enterobacteriaceae correctly speciated became 93%.
Evaluation of Reagent-Impregnated Coagulase-Mannitol Test Strip for Speciation of Staphylococci
Washington, John A., Yu, Pauline K. W.

Applied Microbiology | December 5, 2020 | Volume: 19 | Issue: 4 | Pages: 702-703

10.1128/am.19.4.702-703.1970 Get It

A new coagulase-mannitol reagent-impregnated strip test has been evaluated with 322 Micrococcaceae. Mannitol fermentation was determined accurately by this test; however, the coagulase reaction was difficult to interpret and was subject to significant error.
Stability of Barium Sulfate Turbidity Standards
Washington, John A., Warren, Edward, Karlson, Alfred G., Warren, Edward

Applied Microbiology | December 5, 2020 | Volume: 24 | Issue: 6 | Pages: 1013-1013

10.1128/am.24.6.1013-1013.1972 Get It

McFarland barium sulfate standards prepared in 1952 were compared spectrophotometrically with freshly and identically prepared standards; the results were nearly identical.
Evaluation of the Auxotab Enteric 1 System for Identification of Enterobacteriaceae
Washington, John A., Yu, Pauline K. W., Martin, William J., Martin, William J.

Applied Microbiology | December 5, 2020 | Volume: 23 | Issue: 2 | Pages: 298-300

10.1128/am.23.2.298-300.1972 Get It

An evaluation of the accuracy and convenience of the Auxotab Enteric 1 System for identification of Enterobacteriaceae was performed with 160 bacteria. Identification at the species level was correct in 134 (83.8%) instances and at the generic level in 144 (90%) instances. Sixty strains failed to achieve the minimal concentration of organisms required to complete the identification process within 7 hr. The system was judged to be laborious and to present a potential hazard to those working with it.
Hydrogen Sulfide-Producing Variants of Escherichia coli
Maker, Myron D., Washington, John A.

Applied Microbiology | December 5, 2020 | Volume: 28 | Issue: 2 | Pages: 303-305

10.1128/am.28.2.303-305.1974 Get It

Seventeen strains of H 2 S-producing variants of Escherichia coli were isolated from specimens submitted for microbiological study (ten from stool, five from urine, and two from postmortem material). Production of H 2 S was unstable in several strains; however, other than their production of H 2 S, all strains closely resembled typical E. coli in their biochemical reactions. In vitro susceptibilities of the H 2 S-producing variants to antimicrobics closely resembled those of typical E. coli in this laboratory.
Pitfalls in Identification of Methicillin-Resistant Staphylococcus aureus
Marcoux, J. André, Washington, John A.

Applied Microbiology | December 5, 2020 | Volume: 18 | Issue: 4 | Pages: 699-700

10.1128/am.18.4.699-700.1969 Get It

Media and techniques for in vitro testing with respect to screening for methicillin-resistant Staphylococcus aureus are discussed.
Characterization of Micrococcaceae Isolated from Clinical Sources
Person, Donald A., Yu, Pauline K. W., Washington, John A.

Applied Microbiology | December 5, 2020 | Volume: 18 | Issue: 1 | Pages: 95-97

10.1128/am.18.1.95-97.1969 Get It

The characterization of 556 Micrococcaceae isolates from various clinical sources has been presented. The incidence of coagulase-negative mannitol-positive staphylococci was 3.2% and that of coagulase-positive mannitol-negative staphylococci was 1.6%. There appears to be insufficient justification for the routine reporting of staphylococcal variants from a general bacteriology laboratory, and biotyping should be reserved for special circumstances.
Limited usefulness of quantitative culture of blood drawn through the device for diagnosis of intravascular-device-related bacteremia
Paya, C. V., Guerra, Luis H Eraña, Washington, John A., Thompson, Rodney L., Guerra, L, Marsh, Herbert W. , Farnell, M.B.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 27 | Issue: 7 | Pages: 1431-1433

10.1128/jcm.27.7.1431-1433.1989 Get It

The use of a differential quantitative blood culture technique (Isolator) to diagnose intravascular-device-related bacteremia (IDRB) was studied prospectively. During septic episodes in 44 patients, blood was obtained simultaneously through the suspected infected device and from a peripheral venipuncture. The blood samples were processed by the Isolator technique, which enables easy quantification of microorganisms. The cannula was removed, and its tip was cultured semiquantitatively. Of the 52 cannulas studied, 15 were the cause of IDRB, but only 7 of these showed a significantly higher bacterial count in blood obtained through the device compared with peripheral blood. The bacterial count was higher in blood drawn through the device than in peripheral blood in four of six cases that did not fulfill the definition of IDRB. Some blood cultures obtained through the device were positive despite negative cultures of peripheral blood and cannula tips (six cannulas). Quantitative blood cultures were not useful in diagnosing IDRB in this study.
Evaluation of a Reagent-Impregnated Strip for Detection of Nitrate Reduction by Bacterial Isolates
Yu, Pauline K. W., Birk, Robert J., Washington, John A.

American Journal of Clinical Pathology | February 10, 2018 | Volume: 52 | Issue: 6_ts | Pages: 791-793

10.1093/ajcp/52.6_ts.791 Get It