Prevalence, Biomechanics, and Pathologies of the Meniscofemoral Ligaments: A Systematic Review
Deckey, David G. , Tummala, Sailesh V. , Verhey, Jens T. , Hassebrock, Jeffrey D. , Dulle, Donald L., Miller, Mark D. , Chhabra, Anikar , Tummala, Sailesh, Dulle, Donald, Chhabra, Anikar , Hassebrock, Jeffrey D , Tummala, Sailesh V

Arthroscopy, Sports Medicine, and Rehabilitation | November 26, 2021 | Volume: 3 | Issue: 6 | Pages: No page available

10.1016/j.asmr.2021.09.006 Get It

Purpose To systematically review the literature to examine current understanding of the meniscofemoral ligaments (MFLs), their function, their importance in clinical management, and known anatomical variants. Methods A systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta‐Analyses guidelines using PubMed, EMBASE, and Cochrane databases. Studies were included if they reported on the biomechanical, radiographic, or arthroscopic evaluation of human MFLs, or if they reported on an anatomical variant. These were then categorized as cadaveric, radiographic, or clinical. Biomechanical, radiographic, patient‐reported, and functional outcomes data were recorded. Results Forty‐seven studies were included in the qualitative analysis, and 26 of them were included in the quantitative analysis. Of these, there were 15 cadaveric, 3 arthroscopic, and 9 radiographic studies that reported on the prevalence of MFLs. Overall, when looking at all modalities, the presence of either the anterior or posterior MFL (aMFL, pMFL) has been noted to be 70.8%, with it being the aMFL 17.4% and the pMFL 40.6%. The presence of both ligaments occurs in approximately 17.6% of individuals. Eleven reported on mean MFL length and thickness. When evaluating mean length in both men and women, the aMFL has been reported between 21.6 and 28.3 mm and the pMFL length in this population is between 23.4 and 31.2 mm. Five reported on cross‐sectional area. Nine additional papers report anatomical variants. Conclusions This review shows that there continues to be a variable incidence of MFLs reported in the literature, but our understanding of their function continues to broaden. A growing number of anatomic and biomechanical studies have demonstrated the importance of the MFLs in supporting knee stability. Specifically, the MFLs serve an important role in protecting the lateral meniscus and augmenting the function of the posterior cruciate ligament. Clinical Relevance Our findings will aid the clinician in both identifying and treating pathologies of the meniscofemoral ligaments.
A novel meniscofemoral ligament variant intra‐substance to the PCL
Verhey, Jens T. , Deckey, David G. , Dulle, Donald L., Long, Jeremiah R. , Miller, Mark D. , Tummala, Sailesh, Hassebrock, Jeffrey D. , Dulle, Donald, Tummala, Sailesh V , Tummala, Sailesh V. , Chhabra, Anikar

Knee Surgery, Sports Traumatology, Arthroscopy | November 3, 2021 | Volume: 30 | Issue: 7 | Pages: 2277-2280

10.1007/s00167-021-06791-6 Get It

AbstractWhile much detail is known about each anatomic structure of the knee and its contributory effect on biomechanics, our understanding is still evolving. In particular, the function of the meniscofemoral ligaments and their anatomical variants have yet to be fully described. In this report, a never‐before‐described anatomical meniscofemoral ligament variant intra‐substance to the PCL is presented. Arthroscopists should be aware of the novel variant as a growing number of studies have demonstrated the biomechanical importance of the meniscofemoral ligaments in protecting the lateral meniscus and supporting the function of the PCL.Level of Evidence: IV.
Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques
Deckey, David G. , Rosenow, Christian S. , Verhey, Jens T. , Brinkman, Joseph C. , Mayfield, Cory K. , Clarke, Henry D. , Bingham, Joshua S.

The Bone & Joint Journal | May 31, 2021 | Volume: 103-B | Issue: 6 Supple A | Pages: 74-80

10.1302/0301-620x.103b6.bjj-2020-2003.r1 Get It

Aims Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA. Methods A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed. Results In all, 103 M-TKAs and 96 RA-TKAs were included. In RA-TKA versus M-TKA, respectively: mean femoral positioning (0.9° (SD 1.2°) vs 1.7° (SD 1.1°)), mean tibial positioning (0.3° (SD 0.9°) vs 1.3° (SD 1.0°)), mean posterior tibial slope (-0.3° (SD 1.3°) vs 1.7° (SD 1.1°)), and mean mechanical axis limb alignment (1.0° (SD 1.7°) vs 2.7° (SD 1.9°)) all deviated significantly less from the plan (all p < 0.001); significantly fewer knees required a distal femoral recut (10 (10%) vs 22 (22%), p = 0.033); and deviation from planned polyethylene thickness was significantly less (1.4 mm (SD 1.6) vs 2.7 mm (SD 2.2), p < 0.001). Conclusion RA-TKA is significantly more accurate and precise in planning both component positioning and final polyethylene insert thickness. Future studies should investigate whether this increased accuracy and precision has an impact on clinical outcomes. The greater accuracy and reproducibility of RA-TKA may be important as precise new goals for component positioning are developed and can be further individualized to the patient. Cite this article: Bone Joint J 2021;103-B(6 Supple A):74–80.
Virtual, augmented, and mixed reality applications in orthopedic surgery
Verhey, Jens T. , Haglin, Jack M. , Verhey, Erik M., Hartigan, David E.

The International Journal of Medical Robotics and Computer Assisted Surgery | December 23, 2019 | Volume: 16 | Issue: 2 | Pages: No page available

10.1002/rcs.2067 Get It

AbstractBackgroundInnovation in computer‐assisted surgery (CAS) aims to increase operative accuracy and improve safety by decreasing procedure‐related complications. The application of reality technologies, to CAS has begun to revolutionize orthopedic training and practice.MethodsFor this review, relevant published reports were found via searches of Medline (PubMed) data base using the following medical subject headings (MeSH) terms: “virtual reality” or “augmented reality” or “mixed reality” with “orthopedics” or “orthopedic surgery” and all relevant reports we utilized.ResultsTrainees now have authentic and highly interactive operative simulations without the need for supervision. The practicing orthopedic surgeon is better able to pre‐operatively plan and intra‐operatively navigate without the use of fluoroscopy, gain access to three‐dimensional reconstructions of patient imaging, and remotely interact with colleagues located outside the operating room.ConclusionThis review provides a current and comprehensive examination of the reality technologies and their applications in Orthopedic surgery.