ABSTRACT The diagnosis of syphilis is challenging and often relies on serologic tests to detect treponemal or nontreponemal antibodies. Recently, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories proposed an update to the syphilis serology testing algorithm, in which serum samples are first tested using a treponema-specific test and positive samples are analyzed with a nontreponemal assay. The goal of this study was to compare the performance of seven treponemal assays (BioPlex 2200 syphilis IgG [Bio-Rad, Hercules, CA], fluorescent treponemal antibody [FTA] assay [Zeus Scientific, Raritan, NJ], Treponema pallidum particle agglutination [TP-PA; Fujirebio Diagnostics, Malvern, PA], Trep-Sure enzyme immunoassay [EIA; Phoenix Biotech, Oakville, Ontario, Canada], Trep-Chek EIA [Phoenix Biotech], Trep-ID EIA [Phoenix Biotech], and Treponema ViraBlot IgG [Viramed Biotech AG, Planegg, Germany]) using serum samples ( n = 303) submitted to our reference laboratory. In addition to testing with these 7 assays, all samples were tested by a rapid plasma reagin (RPR) assay and a treponemal IgM Western blot assay (Viramed ViraBlot). Compared to the FTA assay as the gold standard, the evaluated treponemal tests demonstrated comparable levels of performance, with percent agreement ranging from 95.4% (95% confidence interval, 92.3 to 97.3) for the Trep-Sure EIA to 98.4% (96.1 to 99.4) for the Trep-ID EIA. Compared to a “consensus of the test panel” (defined as at least 4 of 7 treponemal tests being in agreement), the percent agreement ranged from 95.7% (92.7 to 97.5) for Trep-Sure to 99.3% (97.5 to 99.9) for Trep-ID. These data may assist clinical laboratories that are considering implementing a treponemal test for screening or confirmatory purposes.
Multiplex Detection of IgM and IgG Class Antibodies toToxoplasma gondii, Rubella Virus, and Cytomegalovirus Using a Novel Multiplex Flow Immunoassay
ABSTRACTThe goal of this study was to evaluate the BioPlex 2200Toxoplasma, rubella, and cytomegalovirus (CMV) (ToRC) IgG and IgM multiplex immunoassays (Bio-Rad Laboratories, Hercules, CA) and compare the results to those of conventional testing by enzyme immunoassay (EIA) and enzyme-linked fluorescent assay (ELFA). Serum specimens (n= 600) submitted for routine ToRC IgG and IgM testing by EIA (SeraQuest, Doral, FL; Diamedix, Miami, FL) or ELFA (Vidas; bioMérieux, Durham, NC) were also tested by the BioPlex ToRC multiplex immunoassays. Samples showing discordant results were retested by both methods, with further discrepancies being arbitrated by a third assay. Following repeat testing, the BioPlexToxoplasma, rubella, and CMV IgG assays demonstrated agreements of 98.7 (592/600 specimens), 93.3 (560/600 specimens), and 98.3% (590/600 specimens), respectively, while the ToRC IgM assays yielded agreements of 91.2 (547/600 specimens), 87.3 (524/600 specimens), and 95.2% (571/600 specimens), respectively. The BioPlex ToRC IgG assays provided results comparable to EIA/ELFA results, with kappa coefficients showing near-perfect agreement for theToxoplasma(κ = 0.94) and CMV (κ = 0.97) IgG assays and substantial agreement for the rubella IgG assay (κ = 0.66). The BioPlex ToRC IgM assays showed lower specificity with only slight agreement forToxoplasmaIgM (κ = 0.07), poor agreement for rubella IgM (κ = −0.03), and moderate agreement for CMV IgM (κ = 0.55). Both the BioPlex IgG and IgM assays reduced turnaround time (1.7 h versus 5.5 h by EIA/ELFA for 100 specimens) and eliminated the necessity to manually pipette or aliquot specimens prior to testing.
Evaluation of the Bio-Rad BioPlex 2200 Syphilis Multiplex Flow Immunoassay for the Detection of IgM- and IgG-Class Antitreponemal Antibodies
ABSTRACT The laboratory diagnosis of syphilis is based primarily upon serologic findings. Historically, serologic testing for syphilis has relied on assays such as rapid plasma reagin, fluorescent treponemal antibody absorption, Treponema pallidum particle agglutination (TP-PA), and more recently, enzyme immunoassay (EIA). In this study, we evaluated the performance of a novel multiplex flow immunoassay (BioPlex 2200 Syphilis; Bio-Rad Laboratories, Hercules, CA) for the detection of antitreponemal IgG- and IgM-class antibodies. Serum specimens ( n = 1,008) submitted for routine treponema-specific antibody testing by syphilis IgM and IgG EIA (Trep-Chek; Phoenix-Biotech, Mississauga, Ontario, Canada) were also analyzed by the BioPlex Syphilis multiplex assay. Specimens showing discordant results were repeat tested, with further discrepancies being arbitrated by TP-PA. Compared directly to the results of EIA, the BioPlex IgG assay demonstrated 98.7% (77/78) sensitivity and 99.4% (916/930) specificity. Compared to the Trep-Chek IgM EIA, the BioPlex IgM assay showed 80% (4/5) sensitivity and 97.9% (652/666) specificity. These results indicate that the BioPlex Syphilis multiplex assay shows similar serological agreement with EIA while allowing for a fully automated random-access platform that provides faster (1.7 h for 100 samples versus 4.5 h by EIA) and higher-throughput (800 samples per 9 h versus 200 samples by EIA) analysis of the syphilis serologic response.
Evaluation of Three Multiplex Flow Immunoassays Compared to an Enzyme Immunoassay for the Detection and Differentiation of IgG Class Antibodies to Herpes Simplex Virus Types 1 and 2
ABSTRACT The diagnosis of herpes simplex virus (HSV) infections is routinely made based on clinical findings and supported by laboratory testing using PCR or viral culture. However, in instances of subclinical or unrecognized HSV infection, serologic testing for IgG class antibodies to type-specific HSV glycoprotein G (gG) may be useful. This study evaluated and compared the performances of three multiplex flow immunoassays (AtheNA Multi-Lyte [Zeus Scientific], BioPlex 2200 [Bio-Rad Laboratories], and Plexus HerpeSelect [Focus Diagnostics]) for the simultaneous detection of gG type-specific IgG antibodies to HSV types 1 and 2 (HSV-1 and HSV-2). Serum specimens ( n = 505) submitted for routine gG type-specific HSV IgG testing by enzyme immunoassay (EIA) (HerpeSelect; Focus Diagnostics) were also tested by the three multiplex flow immunoassays. Specimens showing discordant results were tested by HSV type-specific Western blotting (WB). For HSV-1 IgG, the AtheNA, BioPlex, and Plexus assays demonstrated agreements of 94.9% (479/505 specimens), 97.8% (494/505 specimens), and 97.4% (492/505 specimens), respectively, with the results of EIA. For HSV-2 IgG, the AtheNA, BioPlex, and Plexus assays showed agreements of 87.9% (444/505 specimens), 97.2% (491/505 specimens), and 96.8% (489/505 specimens), respectively, with EIA results. Timing studies showed that the AtheNA, BioPlex, and Plexus assays could provide complete analysis of 90 serum specimens in 3.1, 1.5, and 2.9 h, respectively, versus 3.1 h by EIA. These findings suggest that the gG type-specific HSV IgG multiplex immunoassays may be beneficial to high-volume clinical laboratories experiencing significant increases in the number of specimens submitted for HSV serologic testing. The evaluated systems provide comparable results to those of EIA, while reducing hands-on time and eliminating the necessity to aliquot specimens prior to testing.
Detection of
Coccidioides
Species in Clinical Specimens by Real-Time PCR
ABSTRACT Coccidioides spp. are dimorphic fungal pathogens endemic to the semiarid regions of North, Central, and South America. Currently, direct smear and culture are the most common means of identifying Coccidioides spp. While these methods offer relatively sensitive and specific means of detecting Coccidioides spp., growth in culture may take up to 3 weeks, potentially delaying the diagnosis and initiation of appropriate antifungal therapy. In addition, growth of the organism represents a significant safety risk to laboratory personnel. The need for a rapid and safe means of diagnosing coccidioidomycosis prompted us to develop a real-time PCR assay to detect Coccidioides spp. directly from clinical specimens. Primers and fluorescent resonance energy transfer (FRET) probes were designed to target the internal transcribed spacer 2 region of Coccidioides . The assay's limit of detection is below 50 targets per reaction. An analysis of 40 Coccidioides sp. clinical isolates grown in culture demonstrated 100% sensitivity of the assay. A cross-reactivity panel containing fungi, bacteria, mycobacteria, and viruses was tested and demonstrated 100% specificity for Coccidioides spp. An analysis of 266 respiratory specimens by LightCycler PCR demonstrated 100% sensitivity and 98.4% specificity for Coccidioides spp. compared with culture. Analysis of 66 fresh tissue specimens yielded 92.9% sensitivity and 98.1% specificity versus those of the culture method. The sensitivity of the assay testing 148 paraffin-embedded tissue samples is 73.4%. A rapid method for the detection of Coccidioides spp. directly from clinical material will greatly assist in the timely diagnosis and treatment of patients, while at the same time decreasing the risk of accidental exposure to laboratory personnel.